CD33 Antibody, anti-human
Synonyms: Siglec-3, p67, My9
EXTENDED VALIDATION
Bioz Star94/100 Bioz rating
91 Citations21 Images
Clone:
AC104.3E3
Type of antibody:
Primary antibodies
Isotype:
mouse IgG1λ
Applications:
FC, MC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for CD33 Antibody, anti-human

Flow cytometry applications
APC
APC-Vio 770
Biotin
FITC
PE
PE-Vio 770
VioBlue
Recommended dilution:
1:50
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-113-907, 130-113-345
Description:
Human peripheral blood mononuclear cells (PBMCs) were stained with CD33 antibodies as well as with CD14 antibodies and analyzed by flow cytometry using the MACSQuant® Analyzer. The Tandem Signal Enhancer has been used to increase binding specificity of tandem-dye–conjugated antibodies. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application image
Mass cytometry applications
pure
Conjugate:
pure
Used products:
130-108-039
Extended validation for CD33 Antibody, anti-human
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with AC104.3E3
REA775
high
HIM3-4
low
Hu9a (Gemtuzumab Biosimilar)
low
P67.6
partial
WM-53
high

Cells were incubated with an excess of purified unconjugated CD33 (AC104.3E3) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD33. Human peripheral blood mononuclear cells (PBMCs) were stained with CD33 antibodies and with a suitable counterstaining. As a control, CD33 antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD33 (AC104.3E3). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for CD33 Antibody, anti-human
Overview

Clone AC104.3E3 recognizes the human CD33 antigen, a 67 kDa glycoprotein belonging to the sialoadhesin superfamily. The CD33 antigen is highly expressed on human monocytes but weakly on granulocytes and some – but not all – myeloid dendritic cells. The CD33 antigen is also found on myeloid progenitor cells (CFU-GEMM, CFU GM, CFU-G, BFU-E) but is not expressed on lymphocytes, platelets, erythrocytes, or primitive hematopoietic stem cells.

Alternative names

Siglec-3, p67, My9

Detailed product information

Technical specifications

Clone
AC104.3E3
Clonality
monoclonal
Isotype
mouse IgG1λ
Isotype control
Isotype Control Antibody, mouse IgG1
Host
mouse
Type of antibody
Primary antibodies
Species reactivity
human, non-human primate
Cross-reactivity
rhesus monkey (Macaca mulatta), cynomolgus monkey (Macaca fascicularis)
Antigen
CD33
Molecular mass of antigen [kDa]
38
Distribution of antigen
dendritic cells, granulocytes, Langerhans cells, macrophages, mast cells, monocytes, myeloid leukemia cells, NK cells, T cells, basophils, leukemia cells
Entrez Gene ID
RRID
AB_2726124, AB_2726402, AB_2726126, AB_2726125, AB_2726403, AB_2726398, AB_2726397, AB_2660358, AB_2726401, AB_2726120, AB_2726121, AB_2726400, AB_2726123, AB_2726122, AB_2726399
Resources for CD33 Antibody, anti-human
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

You have previously chosen International as your location.
What do you want to do?