Close-up on the loading of the MACSQuant Tyto Cartridge into the MACSQuant Tyto Cell Sorter.
Close-up on the loading of the MACSQuant Tyto Cartridge into the MACSQuant Tyto Cell Sorter.
Logo

Cell sorting of immune cells

Smart and gentle sorting of T cells, B cells, NK cells, TILs, and more

The MACSQuant® Tyto® Family of cell sorters is designed to meet the unique challenges of immune cell sorting. The gentle microchip-based sorting technology prevents immune cell activation and preserves cell functionality, while the closed cartridges keep samples sealed and sterile, ensuring a contamination-free workflow. Sort and re-sort even the most delicate or rare immune cells with high purity and yield.

Choose your application of interest

Rare but essential: Isolating antigen-specific T cells

Due to their exceptional specificity, antigen-specific T cells are extraordinarily diverse and rare, therefore challenging to isolate and analyze. The gentle sorting of the MACSQuant Tyto Cell Sorter enables precise detection and sorting of these rare T cells, while the disposable cartridge ensures sterile sorting, for contamination-free cultivation and expansion of the sorted cells.

Flow cytometry analysis showing enrichment of antigen-specific T cells after cell sorting on the MACSQuanrt Tyto Cell Sorter using MHC MACSimers.
Gentle and sterile cell sorting of antigen-specific T cells to high purity using the MACSQuant Tyto Cell Sorter.

In this study, rare antigen-specific T cells were successfully isolated from human peripheral blood mononuclear cells (PBMCs) to a purity superior to 97% using the MACSQuant Tyto Cell Sorter and MHC MACSimers.

Seamlessly integrate cell sorting in your T cell analysis workflow. Discover our workflow for enrichment and analysis of antigen-specific T cells.

No cell population left behind: Sequential sorting made simple

With the MACSQuant Tyto Cell Sorter, every cell counts. Unlike conventional droplet sorters, both positive and negative fractions can be easily retrieved and re-sorted. The closed, flexible design of the MACSQuant Tyto Cartridge streamlines target cell enrichment, enabling precise, step-by-step isolation of diverse cell types – all from the same starting sample.

Infographic of sequential cell sorting of cell populations from PBMCs using the MACSQuant Tyto Cartridge.
Sorting strategy for sequential sorting of PBMC-derived cell populations using the MACSQuant Tyto Cell Sorter.

Each sorting round gently isolates distinct cell populations from a heterogeneous mix, such as human peripheral blood mononuclear cells (PBMCs) or tumor-infiltrating lymphocytes (TILs).

Check out the infographic showcasing a sequential sorting strategy for isolating PBMC-derived cell populations. Cells were sorted in three passes, each targeting a distinct lymphocyte population:

  • Population 1: CD19+ B cells
  • Population 2: CD8+ T cells
  • Population 3: CD3–CD14–CD56+CD16+ NK cells.

Freshly isolated PBMCs are the starting material for the initial B cell sort. The negative fraction is used as starting material for the subsequent T cell sort. Finally, the negative fraction from the T cell sort is the starting material for the NK cell sort. To ensure sterility, new cartridges are used for each sort.

Below you can dive into real data using this sorting strategy in the MACSQuant Tyto Cell Sorter.

Flow cytometry analysis showing sequential cell sorting of immune cell populations from PBMCs on the MACSQuant Tyto Cell Sorter, without compromising cell viability.
Sequential sorting of PBMC-derived B cells, T cells, and NK cells to high purity using the MACSQuant Tyto Cell Sorter.

Check our data on the successful isolation of B, T, and NK cells from a single PBMC population by sequential cell sorting using the MACSQuant Tyto Cell Sorter. All three sorting steps resulted in highly pure target cell populations with viabilities above 98%.

Sorting of NK cells to high purity using the MACSQuant Tyto Cell Sorter.

Dive into our data showing sequential sorting of two major subtypes of NK cells from a single PBMC population: Regulatory CD56hiCD16– NK cells and classical CD56+CD16+ NK cells. Both sorting steps resulted in highly pure target cell populations without compromising cell viability.

Gentle precision: Sorting delicate immune cells with confidence

With a short lifespan, fragile cellular structure, and high sensitivity to environmental changes, neutrophils are very delicate immune cells, highly susceptible to activation, damage, or apoptosis during handling. Therefore, gentle isolation is a critical step for the accurate analysis of their function.

Flow cytometry analysis showing enrichment of neutrophils after cell sorting on the MACSQuant Tyto Cell Sorter, without compromising cell viability and without cellular activation.
Sorting of neutrophils to high purity using the MACSQuant Tyto Cell Sorter.

In this study, neutrophil granulocytes from non-lysed whole blood were sorted to high purity using the MACSQuant Tyto Cell Sorter. Downstream evaluation of activation and naive markers confirmed that the gentle sorting effectively prevented cell activation and preserved cell functionality.

You have previously chosen International as your location.
What do you want to do?