CD11c Antibody, anti-mouse
Synonyms: ITGAX, CR4, p150, 95, CR4, integrin αX, N418
EXTENDED VALIDATION
Bioz Star96/100 Bioz rating
1230 Citations236 Images
Clone:
N418
Type of antibody:
Primary antibodies
Isotype:
hamster IgG
Applications:
FC, MICS, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:

Related products for CD11c Antibody, anti-mouse

Flow cytometry applications
APC
APC-Vio 770
Biotin
FITC
PE
PE-Vio 770
PerCP-Vio 700
Vio Bright B515
VioBlue
Recommended dilution:
1:50
Remark:
Cells should be stained prior to fixation, if formaldehyde is used as a fixative.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-119-762, 130-119-802
Description:
Mouse splenocytes were stained with CD11c antibodies as well was with Anti-MHC Class II antibodies and analyzed by flow cytometry. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence.

Application image
MICS (MACSima Imaging Cyclic Staining) applications
APC
FITC
PE
Fixation:
frozen – PFA
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-119-762, 130-119-802
Testing grade:
Fixation:
frozen – Acetone
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-119-762, 130-119-802
Testing grade:
Extended validation for CD11c Antibody, anti-mouse
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with N418
REA754
high
HL3
high

Cells were incubated with an excess of purified unconjugated CD11c (N418) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD11c. Splenocytes from C57BL/6 mice were stained with CD11c antibodies and plotted against the side scatter. As a control, CD11c antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD11c (N418). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for CD11c Antibody, anti-mouse
Overview

The mouse CD11c antigen is present in dendritic cells in lymphoid organs and blood, in Langerhans cells in the epidermis, in dendritic cell progenitors in the bone marrow, and in in vitro generated bone marrow–derived dendritic cells. In spleen and lymph node, CD11c is expressed at high levels on conventional CD11c+CD45R–mPDCA-1– dendritic cells, and at moderate levels on CD11c+CD45R+ mPDCA-1+ plasmacytoid dendritic cells. Clone N418 is reported to be weakly expressed on NK cells, B cells, and T cell subsets. About 1–3% of splenocytes, 2% of bone marrow cells, as well as <1% of lymph node cells and thymocytes express CD11c.

Alternative names

ITGAX, CR4, p150, 95, CR4, integrin αX, N418

Detailed product information

Technical specifications

Clone
N418
Clonality
monoclonal
Isotype
hamster IgG
Host
hamster
Type of antibody
Primary antibodies
Species reactivity
mouse
Antigen
CD11c
Molecular mass of antigen [kDa]
127
Distribution of antigen
B cells, dendritic cells, granulocytes, macrophages, monocytes, NK cells, T cells, lymphocytes, leukemia cells
Entrez Gene ID
RRID
AB_2660162, AB_2783921, AB_2783920, AB_2783919, AB_2922036, AB_2889434, AB_2660161, AB_2660158, AB_2660164, AB_2660163, AB_2751854, AB_2801981, AB_2751823, AB_2660157, AB_2811411
Resources for CD11c Antibody, anti-mouse
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

You have previously chosen International as your location.
What do you want to do?