When working with the standard MHC MACSimer peptide loading protocol, 200 nmol MACSpep peptide is sufficient for up to 20 peptide loading reactions.
▲ Note: The optimum peptide loading concentration might vary depending on the specific peptide-MHC combination. To define the optimum concentration for an assay, refer to section Tips & tricks for peptide loading.
Preparation of MACSpep single peptides for peptide loading on MHC MACSimers
This application protocol describes the preparation of lyophilized MACSpep single peptides for loading on MHC MACSimers to analyze antigen-specific T cells. Besides peptide preparation, it provides important technical advice and resources for the determination of the optimum peptide loading concentration for each individual application to ensure efficient peptide-MHC loading and antigen-specific T cell staining.
- Spin down the vial briefly before opening.
- Dissolve the pellet by adding 100% DMSO at room temperature according to table 1. Vortex briefly until all lyophilized powder is dissolved.
▲ Note: Information on defining the optimum peptide concentration can be found in sections Tips & tricks for peptide loading and Resources. - Centrifuge at ≥800×g for 30 seconds.
- Aliquot the solution in appropriate volumes to avoid repeated freeze-thaw cycles.
- Close vials tightly and store at –20 °C.
▲ Note: It is recommended to use the dissolved MACSpep peptide within 6 months.
Table 1: Recommended volumes for dissolving MACSpep peptides.
| Final peptide stock concentration (mmol/L) | Final peptide-loading concentration (µmol/L) | DMSO volume (µL) | |
| Recommended standard concentration | 10 | 200 | 20 |
| Alternative concentrations, e.g., for high-affinity peptides or specific peptides with poor water solubility | 5 | 100 | 40 |
| 2.5 | 50 | 80 | |
| 1.25 | 25 | 160 | |
| Lowest recommended concentration for peptides with poor water solubility | 0.125 | 2.5 | 1600 |
Please note that there are a few MACSpep Single Peptide sequences that are very difficult to dissolve in aqueous buffer due to their amino acid sequence and other biochemical properties. For these sequences, it is recommended to buy the peptide-loaded MHC MACSimer version if available, as the peptide-loading using MHC MACSimer FleX Kits might not be feasible.
Table 2: MACSpep Single Peptides not recommended for MHC MACSimer peptide-loading.
| MACSpep Single Peptide sequences that are not recommended for peptide-loading using MACSimer FleX Kits* | Recommended peptide-loaded MHC MACSimer reagent |
| MACSpep EBV LMP2a (FLYALALLL) HLA-A*02 (# 130-134-318) | MHC MACSimer A*0201 EBV LMP2a (FLYALALLL), human (# 130-134-621) |
| MACSpep EBV LMP2a (CLGGLLTMV) HLA-A*02 (# 130-134-316) | MHC MACSimer A*0201 EBV LMP2a (CLGGLLTMV), human (# 130-134-622) |
| MACSpep EBV LMP2a (PYLFWLAAI) HLA-A*24 (# 130-134-348) | MHC MACSimer A*2402 EBV LMP2a (PYLFWLAAI), human (# 130-134-633) |
| MACSpep KRAS G12V (KLVVVGAVGV) HLA-A*02 (# 130-136-064) | MHC MACSimer A*0201 KRAS-G12V (KLVVVGAVGV), human (# 130-136-355) |
| MACSpep NY-ESO-1 (SLLMWITQC) HLA-A*02 (# 130-134-555) | MHC MACSimer A*0201 NY-ESO-1 (SLLMWITQC), human (# 130-135-302) |
| MACSpep NY-ESO-1 (SLLMWITQV) HLA-A*02 (# 130-134-554) | Currently not available |
| MACSpep IAV MP1 (GILGFVFTL) HLA-A*02 (# 130-136-110) | MHC MACSimer A*0201 IAV MP1 (GILGFVFTL), human (# 130-134-624) |
| *MACSpep Single Peptides sequences can still be used for T cell expansion purposes. | |
A short guide for peptide selection and loading can be downloaded here: Peptide loading using MHC MACSimer Flex Kits
- A short guide for peptide selection and loading can be downloaded here: Peptide loading using MHC MACSimer Flex Kits
- For peptide loading on MHC MACSimers, a final peptide loading concentration of 10 mmol/L is recommended. However, depending on the specific combination of peptide and MHC, the affinity and thus optimum peptide loading concentration can greatly vary. It is therefore recommended to check the predicted peptide binding affinity to the intended MHC allele using one of the online prediction tools listed in section Resources. Whilst medium to low affinity peptides will benefit from the recommended concentration of 10 mmol/L, loading of a high affinity peptide might be more efficient at lower concentrations.
- Depending on the hydrophobicity of the peptide, the optimum concentration for MHC MACSimer peptide loading might vary. A peptide with a poor water solubility can lead to precipitation or aggregation of the MACSimer. This will be visible as a pellet after centrifugation or elevated background signal in flow cytometry. For these peptides, it is recommended to use a lower concentration in the final peptide loading reaction.
- Depending on the natural MHC restriction, every peptide can bind to one or more specific MHC alleles. Binding stability strongly depends on individual biochemical parameters of every application. By providing this product, binding of the respective peptide to any intended MHC complex is not guaranteed.
Negative control
Depending on the experimental setup, allele-matched MHC MACSimer Negative Controls can be ordered that carry:
- a non-sense peptide sequence for human MHC class I alleles or
- a CLIP peptide (MHC class II-associated invariant chain)* for human MHC II alleles or
- a peptide sequence unrelated to the experiment
*CLIP is a fragment of the invariant chain (CD74) that in vivo stabilizes MHC class II during expression before it is replaced by an exogenous peptide in the endolysosome.
Positive control
For positive staining control, it is recommended to use allele-matched MHC MACSimers that recognize epitopes derived from viruses that are widespread in the human population and known to bind well to the corresponding MHC allele of interest (for instance cytomegalovirus (CMV), Epstein-Barr virus (EBV), and Influenza A virus (IAV)). It is important to keep in mind that even if the donor of the cell material is known to be positive for, e.g., HLA-A*02:01 and CMV, there is still no 100 % guarantee that the donor actually expresses T cell receptors (TCRs) that recognize commonly used epitopes such as CMV pp65 (NLVPMVATV, sequence section 495-503). Every individual responds to different epitopes, which is why in most cases antigen-specific T cell analytics are highly personalized.
The most reliable positive control strategy is the parallel staining of a (transduced) cell line that is known to express only one TCR type, specific for the antigen of interest, if available.
Table 2: Recommendations for positive controls. This table gives suggestions for allele-matched positive control sequences. In brackets, experimentally determined frequencies of healthy donors who had positive responses of >=0.1% among CD8+ T cells in a multimer staining on PBMCs are given. Note that no statistical significance is guaranteed for these values. These values are only experimental findings from the donor cohorts. The frequencies may vary drastically depending on the regional and demographic characteristics of a donor and should therefore be used as an approximate reference only.
| Allele | Peptide | Order number |
| A*01:01 | CMV pp50 (VTEHDTLLY) [30% response rate in 10 donors tested] IVA PB1 (VSDGGPNLY) [43% response rate in 7 donors tested] | 130-134-314 130-135-273 |
| A*02:01 | CMV pp65 (NLVPMVATV) [26% response rate in 19 donors tested] EBV LMP2a (FLYALALLL) [17% response rate in 18 donors tested] | 130-134-090 130-134-318 |
| A*11:01 | EBV EBNA4 (IVTDFSVIK) [50% response rate in 8 donors tested] | 130-134-326 |
| A*24:02 | CMV IE-1 (AYAQKIFKI) [18% response rate in 11 donors tested] | 130-134-292 |
| B*07:02 | EBV EBNA3 (RPPIFIRRL) [73% response rate in 11 donors tested] CMV pp65 (RPHERNGFTVL) [25% response rate in 12 donors tested] CMV pp65 (TPRVTGGGAM) [25% response rate in 12 donors tested] | 130-134-330 130-134-298 130-134-295 |
| B*08:01 | EBV EBNA3 (FLRGRAYGL) [80% response rate in 10 donors tested] EBV BZLF1 (RAKFKQLL) [100% response rate in 9 donors tested] CMV IE1 (ELRRKMMYM) [33% response rate in 9 donors tested] | 130-134-331 130-134-332 130-134-283 |
| B*15:01 | EBV EBNA4 (GQGGSPTAM)** | 130-134-334 |
| B*35:01 | EBV EBNA1 (HPVGEADYFEY) [57% response rate in 7 donors tested] EBV BZLF1 (EPLPQGQLTAY) [71% response rate in 7 donors tested] CMV pp65 (IPSINVHHY) [43% response rate in 7 donors tested] | 130-134-338 130-134-337 130-134-297 |
| H-2Kb | OVA (SIINFEKL) | 130-136-208 |
**In internal experiments, cell staining with this antigen could only be achieved on low antigen-specific T cell frequencies after enrichment of positive T cells from PBMCs with subsequent expansion for 14 days on feeder cells.
Peptide affinity prediction tools and literature
Peptide binding affinity tools provided by the Department of Health Technology, Technical University of Denmark
MHC I: NetMHCpan 4.1 - DTU Health Tech - Bioinformatic Services
MHC II: NetMHCIIpan 4.3 - DTU Health Tech - Bioinformatic Services
Reynisson B. et al. (2020) NetMHCpan-4.1 and NetMHCIIpan-4.0: improved predictions of MHC antigen presentation by concurrent motif deconvolution and integration of MS MHC eluted ligand data, Nucleic Acids Res 48(W1):W449-W454
Peptide binding affinity tools provided by the SYFPEITHI database
SYFPEITHI: Epitope prediction
Rammensee H., et al. (1999) SYFPEITHI: database for MHC ligands and peptide motifs, Immunogenetics, 50(3-4):213-9.
Peptide binding affinity tools provided by the The Immune Epitope Database (IEDB)
Consensus 2.22 MHC-II Binding (iedb.org)
MHC-II Help (iedb.org)
GRAVY score
One possible indicator for peptide-water solubility is the grand average of hydropathy (GRAVY) score, which can be calculated with a variety of web tools. If the GRAVY score of a peptide is >1, a lower peptide-loading concentration might be necessary to ensure optimal loading conditions. Note that the GRAVY score cannot serve as sole point of reference to define the optimum peptide-loading concentration.
151 products found
|
USD70.00
(excl. tax)
USD135.00
(excl. tax)
For research use only
USD70.00
(excl. tax)
For research use only
USD70.00
(excl. tax)
For research use only
USD70.00
(excl. tax)
For research use only
USD105.00
(excl. tax)
For research use only
For research use only
200 nmol
(excl. tax)
For research use only
USD70.00
(excl. tax)
For research use only
USD70.00
(excl. tax)
For research use only
USD70.00
(excl. tax)
USD70.00
(excl. tax)
For research use only
USD105.00
(excl. tax)
For research use only
USD70.00
(excl. tax)
For research use only
For research use only
200 nmol
(excl. tax)
For research use only
USD70.00
(excl. tax)
For research use only
For research use only
200 nmol
(excl. tax)
For research use only
USD105.00
(excl. tax)
For research use only
USD135.00
(excl. tax)
For research use only
USD70.00
(excl. tax)
For research use only
For research use only
200 nmol
(excl. tax)
For research use only
USD70.00
(excl. tax)
For research use only
USD70.00
(excl. tax)
For research use only
USD70.00
(excl. tax)
For research use only
USD70.00
(excl. tax)
For research use only
USD70.00
(excl. tax)
You have previously chosen International as your location.
What do you want to do?