CD14 Antibody, anti-human
Synonyms: LPS R
EXTENDED VALIDATION
Bioz Star97/100 Bioz rating
679 Citations106 Images
Clone:
TÜK4
Type of antibody:
Primary antibodies
Isotype:
mouse IgG2aκ
Applications:
FC, MICS, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for CD14 Antibody, anti-human

Flow cytometry applications
APC
APC-Vio 770
Biotin
FITC
PE
PE-Vio 615
PE-Vio 770
PerCP
PerCP-Vio 700
VioBlue
VioGreen
Recommended dilution:
1:50
Remark:
Cells should be stained prior to fixation, if formaldehyde is used as a fixative.
Conjugate:
APC
Used products:
130-113-143, 130-113-705
Description:
Human peripheral blood mononuclear cells (PBMCs) were stained with CD14 antibodies and analyzed by flow cytometry using the MACSQuant® Analyzer. The Tandem Signal Enhancer has been used to increase binding specificity of tandem-dye–conjugated antibodies. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application image
MICS (MACSima Imaging Cyclic Staining) applications
APC
FITC
PE
Fixation:
frozen – PFA
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC, ICC
Conjugate:
APC
Used products:
130-113-143, 130-113-705
Testing grade:
Fixation:
frozen – Acetone
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-113-143, 130-113-705
Testing grade:
Extended validation for CD14 Antibody, anti-human
Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD14. Human peripheral blood mononuclear cells (PBMCs) were stained with CD14 antibodies and with a suitable counterstaining. As a control, CD14 antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD14 (TÜK4). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for CD14 Antibody, anti-human
Overview

Clone TÜK4 recognizes the human CD14 antigen and cross-reacts with non-human primate CD14. The CD14 antigen is a high affinity receptor for lipopolysaccharides (LPS) and LPS–binding protein (LBP)–complexes. It is part of the functional heteromeric LPS receptor complex comprised of CD14, TLR4, and MD-2.

CD14 is strongly expressed on most human monocytes and macrophages in peripheral blood, other body fluids, and various tissues, such as lymph nodes and spleen. CD14 is expressed at high levels, also on a few CD1c (BDCA-1)+ CD2+ myeloid dendritic cells and at low levels on neutrophilic granulocytes. Ex vivo differentiation of monocytes to dendritic cells is associated with down–regulation of CD14 antigen expression.

Alternative names

LPS R

Detailed product information

Technical specifications

Clone
TÜK4
Clonality
monoclonal
Isotype
mouse IgG2aκ
Isotype control
Isotype Control Antibody, mouse IgG2a
Host
mouse
Type of antibody
Primary antibodies
Species reactivity
human, non-human primate, other
Cross-reactivity
rhesus monkey (Macaca mulatta), cynomolgus monkey (Macaca fascicularis), pigtail monkey (Macaca nemestrina), cotton-top tamarin (Saguinus oedipus), pig, cow, sheep, goat, dog, mink, rabbit
Antigen
CD14
Molecular mass of antigen [kDa]
37
Distribution of antigen
B cells, dendritic cells, epithelial cells, granulocytes, Langerhans cells, macrophages, monocytes, osteoclasts, platelets, plasma cells, liver
Entrez Gene ID
RRID
AB_2725979, AB_2725973, AB_2726248, AB_2726256, AB_2725980, AB_2725978, AB_2726255, AB_2725971, AB_2726247, AB_2725974, AB_2726251, AB_2725976, AB_2725972, AB_2726254, AB_2726246, AB_2726249, AB_2726250, AB_2726253, AB_2725981, AB_2725975, AB_2726252, AB_2725977
Resources for CD14 Antibody, anti-human
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support