CD101 Antibody, anti-human
Synonyms: EWI-101, IGSF2, V7, p126
EXTENDED VALIDATION
Bioz Star93/100 Bioz rating
5 Citations
Clone:
BB27
Type of antibody:
Primary antibodies
Isotype:
mouse IgG1κ
Applications:
FC, MICS, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for CD101 Antibody, anti-human

Flow cytometry applications
APC
Biotin
PE
PE-Vio 770
Vio Bright FITC
Recommended dilution:
1:11
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-095-132
Description:
Human peripheral blood mononuclear cells (PBMCs) were stained with CD101 antibodies as well as with CD4 antibodies and analyzed by flow cytometry using the MACSQuant® Analyzer. The Tandem Signal Enhancer has been used to increase binding specificity of tandem-dye–conjugated antibodies. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application image
MICS (MACSima Imaging Cyclic Staining) applications
APC
PE
Fixation:
frozen – PFA
Species tested:
human
Recommended dilution:
1:11
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC, ICC
Conjugate:
APC
Used products:
130-095-132
Testing grade:
Fixation:
frozen – Acetone
Species tested:
human
Recommended dilution:
1:11
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-095-132
Testing grade:
Extended validation for CD101 Antibody, anti-human
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with BB27
REA954
high
V7.1
low

Cells were incubated with an excess of purified unconjugated CD101 (BB27) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD101. Human peripheral blood mononuclear cells (PBMCs) were stained with CD101 antibodies and with a suitable counterstaining. As a control, CD101 antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD101 (BB27). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for CD101 Antibody, anti-human
Overview

Clone BB27 recognizes the CD101 antigen, also known as V7 or IGSF2, which is a 140 kDa type I transmembrane glycoprotein of the Ig gene superfamily. CD101 is expressed on monocytes, granulocytes, and subsets of dendritic cells (DCs). In addition, CD101 is expressed on certain subpopulations of T cells, in particular about 5–30% of FoxP3+ Treg cells in peripheral blood.

The interaction of CD101 with the antibody BB27 has been shown to inhibit T cell activation by allogeneic DCs or CD3 antibodies.

Alternative names

EWI-101, IGSF2, V7, p126

Detailed product information

Technical specifications

Clone
BB27
Clonality
monoclonal
Isotype
mouse IgG1κ
Isotype control
Isotype Control Antibody, mouse IgG1
Host
mouse
Type of antibody
Primary antibodies
Species reactivity
human
Antigen
CD101
Molecular mass of antigen [kDa]
113
Distribution of antigen
dendritic cells, granulocytes, Langerhans cells, monocytes, red blood cells, T cells, lymphocytes, leukemia cells, thymocytes, lung, small intestine, spleen
Entrez Gene ID
RRID
AB_10827694, AB_10829614, AB_2661058, AB_2661057, AB_2661055, AB_10828923, AB_2661056
Resources for CD101 Antibody, anti-human
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support