Perforin Antibody, anti-human, REAfinity™
Synonyms: PRF1, FLH2, HPLH2, P1, PFN1, PFP
RECOMBINANT EXTENDED VALIDATION
Bioz Star93/100 Bioz rating
17 Citations1 Image
Clone:
REA1061 | dG9
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
ICFC, MC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for Perforin Antibody, anti-human, REAfinity™

Intracellular flow cytometry applications
APC-Vio 770
PE-Vio 770
Vio B515
VioGreen
Description:
Fixed and permeabilized human peripheral blood mononuclear cells (PBMCs) were stained with Anti-Perforin antibodies or with the corresponding REA Control (I) antibodies (left images) as well as with CD8 antibodies. Cells were analyzed by flow cytometry using the MACSQuant® Analyzer. Cell debris were excluded from the analysis based on scatter signals.
Intracellular flow cytometry applications
APC
APC-Vio 770
FITC
PE
PE-Vio 770
Vio B515
Vio R667
VioBlue
VioGreen
Recommended dilution:
1:50
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-118-191, 130-118-118
Description:
Fixed and permeabilized human peripheral blood mononuclear cells (PBMCs) were stained with Anti-Perforin antibodies or with the corresponding REA Control (I) antibodies (left images) as well as with CD8 antibodies. Cells were analyzed by flow cytometry using the MACSQuant® Analyzer. Cell debris were excluded from the analysis based on scatter signals.

Application imageView details view details

Application imageView details view details
Mass cytometry applications
pure
Conjugate:
pure
Used products:
130-126-480
Extended validation for Perforin Antibody, anti-human, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA1061
DG9
high
GG9
high
B-D48
low

Cells were incubated with an excess of purified unconjugated Perforin (REA1061) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for Perforin. Human peripheral blood mononuclear cells (PBMCs) were first stained with Viobility™ Fixable Dye followed by a suitable counterstaining. Cells were then fixed and permeabilized using the Inside Stain Kit followed by intracellular staining with Perforin antibodies. As a control, Perforinantibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and Viobility 405/520 Fixable Dye fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Specifications for Perforin Antibody, anti-human, REAfinity™
Overview

Clone REA1061 recognizes the human perforin, a 70 kDa cytolytic protein, which is expressed by cytotoxic T lymphocytes and natural killer (NK) cells, and which is stored in cytoplasmic granules. Upon cell activation perforin is released and functions as one of the major effector molecule to mediate killing of target cells.

Additional information: Clone REA1061 displays negligible binding to Fc receptors.

Alternative names

PRF1, FLH2, HPLH2, P1, PFN1, PFP

Detailed product information

Technical specifications

Clone
REA1061
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody (I), human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
human
Antigen
Perforin
Molecular mass of antigen [kDa]
59
Distribution of antigen
NK cells, T cells
Entrez Gene ID
RRID
AB_2922362, AB_2922354, AB_2733891, AB_2922353, AB_2733924, AB_2733925, AB_2733890, AB_2922363, AB_2922361, AB_2922352, AB_2733445, AB_2733686, AB_2889728, AB_2733444, AB_2733687

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for Perforin Antibody, anti-human, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support