Bead-based multiplex assays for flow cytometry supported by ready-to-use kits
- High-parameter measurements with up to 39 specificities at the same time
- Perfect match with MACSQuant® Analyzers and Express Modes for fully automated experiment setup, acquisition, and analysis
- Time-saving method compared to other flow cytometry-based multiplex assays
Available MACSPlex Kits
| Application category | Kit name | Number of analytes | Target analytes | MACSQuantify Software version | Express Mode package |
| Human cytokines | MACSPlex Cytokine 12 Kit, human | 12 | IL-2, IL-4, IL-5, IL-6, IL-9, IL-10, IL-12, IL-17A, GM-CSF, IFN-α, IFN-γ, TNF-α | 2.5 and higher | 25.2.9990 and higher |
| Mouse cytokines | MACSPlex Cytokine 10 Kit, mouse | 10 | IL-2, IL-4, IL-5, IL-10, IL-12, IL-17A, IL-23, GM-CSF, IFN-γ, TNF-α | 2.5 and higher | 25.3.10934 and higher |
| Human cytotoxicity | MACSPlex Cytotoxic T/NK Cell Kit, human | 12 | IL-2, IL-4, IL-6, IL-10, IL17A, IL-21, GM-CSF, Granzyme B, IFN-γ, MCP-1, TNF-α, Perforin | 2.13.1 and higher | 213.2.20284 and higher* |
| Human extracellular vesicles (EV) | MACSPlex EV Kit IO, human | 37 EV markers and 2 controls | CD3, CD4, CD19, CD8, HLA-DRDPDQ, CD56, CD105, CD2, CD1c, CD25, CD49e, ROR1, CD209, CD9, SSEA-4, HLA-ABC, CD63, CD40, CD62P, CD11c, CD81, MCSP, CD146, CD41b, CD42a, CD24, CD86, CD44, CD326, CD133/1, CD29, CD69, CD142, CD45, CD31, CD20, CD14, REA control, mIgG1 control | 2.8 and higher | |
| Mouse extracellular vesicles (EV) | MACSPlex EV Kit IO, mouse | 37 EV markers and 2 controls | CD3, CD4, CD19, CD8a, MHC Class II, CD49b, CD105, CD2, CD11b, CD25, CD49e, CD140a, CD66a, CD9, CD205, MHC Class I, CD63, CD40, CD62P, CD11c, CD81, AN2, CD146, CD41, CD61, CD24, CD86, CD44, CD326, Prominin-1, CD29, CD69, CD45, CD31, CD20, CD115, EphA2, REA control, rIgG1 control | 2.8 and higher | |
| Human extracellular vesicles (EV) | MACSPlex EV Kit Neuro, human | 37 EV markers and 2 controls | ErbB-2 (CD340), CD49a, CD140a, CD171, CD56, CD13, CD31, CD222(IGF2R), CD11b, CD24, CD45, CD133/1, O4, GLAST(ACSA-1), CD90, CX3CR1, EGFR, Podoplanin, A2B5, CD29, AN2(CSPG4), CD9, CD63, CD81, CD47, PSA-NCAM, CD44, CD38, CD49f, CD106, CD49e, CD54, CD36, CD107a, CD68, VGLUT2, Ganglioside GD2, REA control, mIgG1 control | 2.8 and higher | |
| Human extracellular vesicles (EV) | MACSPlex EV Kit MSC, human | 37 EV markers and 2 controls | HLA-DR DP DQ, CD119, HLA-DR, CD11b, CD102, anti-Melanoma (MCSP), CD49e, CD90, CD304, CD105, CD14, CD54, CD45, CD79a, CD44, CD49b, CD200, HLA-ABC, CD73, CD19, CD34, CD9, CD63, CD81, CD62P, CD140b, CD31, CD41b, CD13, CD10, CD51/CD61, CD42a, CD166, CD51, CD59, GD2, CD91, REA control, mIgG1 control | 2.8 and higher |
*Note: to get the new Express Mode package please contact your local support team
Basic principle
Samples containing unknown levels of analytes are incubated with the antibody-coated MACSPlex Capture Beads, and analytes bind to the specific antibody. Two detection reagents, composed of a cocktail of either biotin-conjugated or APC-conjugated antibodies specific for the analytes, are added. Consequently, sandwich complexes are formed between the MACSPlex Capture Beads, the analyte, and the Detection Reagent Biotin while the Detection Reagent APC binds to the biotinylated detection antibodies. These complexes can be analyzed based on the fluorescence characteristics.
Standards of known quantities of given analytes are provided with the kit and are used for the quantification of the analytes within the unknown samples.
Prerequisites
For MACSPlex assays a flow cytometer with a blue (e.g. 488 nm) and a red (e.g. 635 nm) laser with the capability to detect FITC, PE, and APC is necessary.
Analysis with MACSQuant Analyzers and Express Modes
When using the MACSQuant Analyzer 10 or MACSQuant X, our MACSplex Kits can be combined with fully automated Express Modes.
By this, an automated gating strategy to populations of interest will be applied and the gates will be automatically adjusted for each data file individually to achieve optimal results.
Furthermore, a one-click batch analysis of all samples belonging to one experiment can be performed to directly compare your data. The concentrations of each analyte will be presented as an exportale table as well as a ready-to-publish graph.
ExpressModes are compatible with the MACSQuant Analyzer 10 and MACSQuant X instruments and with the MACSQuantify™ Software already installed on your MACSQuant Analyzer. For the required software version, please refer to the table above.
Analysis with other instruments
For all users running MACSPlex assays on a different flow cytometer, subsequent analysis can be performed on your computer using third-party software.
Resources
All MACSPlex Kits
5 products found
|