Consistent dry antibody cocktails for flow cytometry assays

StainExpress™ Dry Antibody Cocktails are preformulated multicolor panels dried onto the bottom of standard flow cytometry tubes, increasing assay simplicity and reproducibility.

Our StainExpress Dry Antibody Cocktails are designed to provide robust and consistent workflows for applications demanding the highest level of standardization. By minimizing sources of error and delivering strong lot-to-lot reproducibility, they offer a reliable solution for analytical flow cytometry assays, including those in cell manufacturing.

Note: StainExpress Dry Antibody Cocktails are for research use only (RUO).

Meet the StainExpress Workflow: Less pipetting, fewer errors, faster flow cytometry

Infographic showing the comparison of the conventional flow cytometry assay and flow cytometry assays using StainExpress Dry Antibody Cocktails
Comparison of the conventional workflow and StainExpress Dry Antibody Cocktails.

The StainExpress Technology simplifies flow cytometry by replacing tedious pipetting and manual setup with ready-to-use dry antibody cocktails. Just add your sample, scan the barcode, and speed up your analytical workflows – saving time and reducing errors.

Streamline your flow cytometry assays, choose precision and reproducibility:

  • Quality assured, from lot to lot: Featuring REAfinity® Recombinant Antibodies for consistent, specific results.
  • Efficiency & ease of use: The ready-to-use format minimizes hands-on time. You simply need to add your sample, without tedious pipetting steps.
  • Reduced error probability: Preformulated and predried to deliver consistent antibody composition, eliminate pipetting errors, and reduce experimental variability.
  • High stability: Unlike liquid antibodies, StainExpress Cocktails offer long shelf life at room temperature.
  • Automation: Barcoded tubes enable automated data acquisition and analysis using the Express Modes on your MACSQuant® Analyzer.

Find your fit: A quick product guide for every application

Cocktail nameMarkersApplication
StainExpress Immune Cell Composition Cocktail, humanCD45, CD3, CD4, CD8, CD14, CD19, CD56, CD16, 7-AADImmune cell composition analysis (not for diagnostic use)
CAR T IPC/QC
StainExpress T Cell Subsets Cocktail, humanCD45, CD3, CD4, CD8, 7-AADGeneral T cell analysis
CAR T post-infusion research (not for diagnostic use), with additional liquid CAR detection reagent
StainExpress CAR T Transduction Cocktail, humanCD45, CD3, CD4, CD8, CD14, 7-AADCAR T IPC/QC (with addition of liquid CAR detection reagent)
StainExpress CD19 CAR T Monitoring Cocktail, humanCD45, CD3, CD4, CD8, FMC63 CD19 CAR, 7-AADCAR T post-infusion research (not for diagnostic use)

Please note: all panels are compatible with human blood, leukapheresis products, PBMCs, and other single-cell suspensions

“As a researcher, I've found the StainExpress Antibody Cocktail to be incredibly easy to use, significantly enhancing our workflow efficiency. Its time-saving protocol, coupled with highly reproducible results, has consistently yielded reliable data across multiple experiments. This product is a game-changer for streamlining staining procedures without compromising on quality.”

Simon Lennartz

Explore data sets derived from cell therapy research using StainExpress Dry Antibody Cocktails

By minimizing human error and experimental variation, the StainExpress Dry Antibody Cocktails are optimized for reliable evaluation of purity, identity, and content of CAR T cell populations in analytical flow cytometry assays. Explore their unique benefits on CAR T in-process and quality control (IPC/QC) and CAR T post-infusion research.

Dot plots of flow cytometry analysis using the StainExpress CD19 CAR T Transduction Cocktail for CAR T detection in IPC/QC clinical assays.
StainExpress Dry Antibody Cocktails in CAR T IPC/QC assays.

Precision, compliance, and automation in quality control assays for CAR T research

Check the data on our StainExpress CAR T Cell Transduction Cocktail, designed to simplify the evaluation of CAR transduction efficiency in cell manufacturing workflows. Paired with the CD19 CAR Detection Reagent, it delivers precise, reliable detection of CD19-specific CAR T cells.

Effortless scalability: Paired with MACSQuant Analyzers and Express Modes, StainExpress Dry Antibody Cocktails enable automated analysis and easy scalability, enhancing efficiency in high-throughput IPC/QC processes.

Dot plots from flow cytometry analysis using the StainExpress CD19 CAR T Monitoring Cocktail to detect CAR T cells in patient monitoring.
StainExpress Dry Antibody Cocktails in CAR T post-infusion research.

CAR T monitoring, standardized and simplified

See the data on our StainExpress CD19 CAR T Monitoring Cocktail, designed to simplify and standardize the characterization of CD19 CAR T cells via flow cytometry for CAR T post-infusion research (not for diagnostic use).

Optimized for consistency: The preformulated panels enable standardized workflows and reproducible results, enabling consistent CAR T monitoring research across treatment locations.

Fast and easy: StainExpress Dry Antibody Cocktails streamline sample processing, providing efficient and hassle-free CAR monitoring research.

Dot plots from flow cytometry analysis using StainExpress Dry Antibody Cocktails and CAR detection reagents.
StainExpress Dry Antibody Cocktails can be used in combination with liquid CAR detection reagents.

Maximum flexibility for comprehensive CAR T analysis

See the data combining the StainExpress T Cell Subsets Cocktail with a CAR detection reagent (A) and the StainExpress CD19 CAR T Monitoring Cocktail with additional liquid antibodies (B), enhancing accuracy for a more comprehensive analysis.

Customizable panels: Integrate a CAR detection reagent of your choice, such as BCMA or CD19, or add liquid antibody conjugates in free channels to assess CAR T cell differentiation or exhaustion status; include a MHC multimer for TCR T cell detection. Achieve deeper insights with high-precision, robust CAR T analysis.

Confidence in every assay: Consistent data, proven performance

Explore our comprehensive performance and stability data, providing reliable, high-quality results for your flow cytometry assays – so you can move forward with confidence in every experiment.

Flow cytometric analysis comparing dry and liquid antibodies
StainExpress Dry Antibody Cocktails deliver comparable results to the equivalent liquid reagents.

StainExpress Dry Antibody Cocktails match liquid reagents in performance and reliability

Our StainExpress Dry Antibody Cocktails undergo a specialized drying process that preserves optimal staining performance. Equivalence testing confirms that these dry cocktails deliver comparable staining patterns to the liquid reagents, providing reliable and consistent results in every assay.

Flow cytometric analysis testing the stability of dry and liquid antibodies
Stability testing: Dry versus liquid reagents.

StainExpress Dry Antibody Cocktails show long-term stability at room temperature

The StainExpress Technology stabilizes antibodies in a dried format, enabling long-term storage without refrigeration. Unlike liquid alternatives, these preformulated panels remain highly stable at room temperature, preventing antibody degradation due to inadequate refrigeration during handling. This minimizes assay variability while simplifying inventory management and providing consistent quality over time.

Master CAR T cell manufacturing: CMEP training

Advance your CAR T cell manufacturing workflows and accelerate personnel qualification with our comprehensive training program. Gain hands-on experience and expert support for analytical method qualification in IPC/QC processes using StainExpress Dry Antibody Cocktails and other key technologies.

All StainExpress Dry Antibody Cocktails products

4 products found

|