Vio® Bright FITC Fluorophore

Vio Bright FITC for blue lasers

The Vio Bright Technology allows to increase the brightness, even of traditional dyes, like FITC. This makes it easier to detect even intracellular markers with low expression levels. At the same time, Vio Bright FITC shows very low spillover into other detection channels which makes it a great choice for complex panel design.

Fluorophore at one glance

LaserBlue (488 nm)
Absorption max.497 nm
Emission max.522 nm
Common filter set (FC)525/50 nm
ApplicationFlow cytometry
Stain index3 out of 5
Fixation stabilityPFA, ethanol, methanol, and acetone

Logo of the VioDyes, fluorochromes for flow cytometry and fluorescence microscopy high fluorescence characterized by intensities and low spillover

Vio Bright FITC is a superior alternative to:

  • FITC
  • Brilliant™ Blue 515
  • Alexa Fluor 488

Characteristics of Vio Bright FITC

Absorption and emission spectra of Vio Bright FITC compared to FITC, Alexa Fluor 488, and BD Horizon Brilliant Blue 515

Absorption and emission spectra of Vio Bright FITC

  • Can be detected with all standard FITC filters
  • No changes in detection filter are required when using Vio Bright FITC instead of FITC

Absorption and emission maxima of fluorochromes related to Vio Bright FITC

FluorochromeAbsorption max. (nm)Emission max. (nm)
Vio Bright FITC496522
FITC495520
Alexa Fluor 488495519
BD Horizon Brilliant Blue 515490515

Flow cytometric analysis to detect CD133/1+ cells using VioBright FITC-conjugated antibodies

Brighter and clearer staining for blue laser

  • Superior choice to detect markers with low expression levels
  • Similar stain index (SI) and mean fluorescence intensity (MFI) as PE
  • Superior brightness compared to FITC

MFI and SI of CD25 (clone 4E3), CD335 (clone 9E2), and CD133/1 (clone AC133) antibodies conjugated to either Vio Bright FITC or PE.

 MFISI
ConjugateVio Bright FITCPEVio Bright FITCPE
CD253.32.05.04.0
CD3354.84.08.511
CD133/13.54.74.74.7

Better gating precision

  • More precise gating due to enhanced brightness, even for weakly expressed antigens

Minimal spillover into other detection channels

  • Compared to FITC only minor spillover into PE channel
  • Only minimal changes in compensation settings required

MFI and SI compared to similar conjugates

ConjugateMFISIMACSQuant Analyzers compensation in channel B2 (%)
MACSQuant VYB compensation in channel Y1 (%)
CD4-Vio Bright FITC661068.50
CD4-FITC29496.50
CD4-PE58126––

Resources

Fluorescence spectra viewer

Analyze the spectral signatures of your fluorochromes to avoid spillover.

Top view on antibody vials with color-coded lids placed in rows

Multicolor flow cytometry panel builder

Design complex multicolor panels with optimized antibody choices, tailored to your experimental setup.

All Vio Bright FITC Products

206 products found

|