CD49b Antibody, anti-mouse, REAfinity™
Synonyms: Itga2, gpIa, VLA-2α, VLA-2alpha, DX5
RECOMBINANT EXTENDED VALIDATION
Bioz Star94/100 Bioz rating
1 Citation
Clone:
REA541 | DX5
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
FC, MICS, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:

Related products for CD49b Antibody, anti-mouse, REAfinity™

Flow cytometry applications
APC
APC-Vio 770
Biotin
PE
PE-Vio 770
PerCP-Vio 700
Vio Bright B515
Recommended dilution:
1:50
Remark:
Cells should be stained prior to fixation, if formaldehyde is used as a fixative.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-120-229, 130-120-303
Description:
Splenocytes from BALB/c mice were stained with CD49b antibodies or with the corresponding REA Control antibodies (left images) and analyzed by flow cytometry using the MACSQuant® Analyzer. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence.

Application imageView details view details

Application imageView details view details
MICS (MACSima Imaging Cyclic Staining) applications
APC
PE
Fixation:
frozen – Acetone
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-120-229, 130-120-303
Testing grade:
Extended validation for CD49b Antibody, anti-mouse, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA541
DX5
high
HMα2
low
REA981
high

Cells were incubated with an excess of purified unconjugated CD49b (REA541) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Specifications for CD49b Antibody, anti-mouse, REAfinity™
Overview

Clone REA541 recognizes the mouse CD49b antigen, a single-pass type I membrane protein also known as integrin alpha-2 (ITGA2). CD49b together with CD29 (ITGB1) forms the adhesion molecule very late antigen-2 (VLA-2), which binds mainly to collagens I, II, and XI. VLA-2 is responsible for adhesion of platelets and other cells to collagens, modulation of collagen and collagenase gene expression, force generation, and organization of newly synthesized extracellular matrix. It is also a receptor for laminins, collagen C-propeptides, and E-cadherin. Mice homozygous for a null mutation in the CD49b gene die very early in embryogenesis. CD49b is expressed on the vast majority of mouse NK cells and on a subset of NKT cells. It is not as mouse strain-restricted as other NK cell markers, for example, NK1.1, and is expressed by most common inbred mouse strains. Bone marrow (BM) resident memory T helper (Tʜ) cells also express CD49b and the homing of adoptively transferred BM memory Tʜ cells to BM can be efficiently blocked by antibodies to CD49b. This points to a decisive role of CD49b in the trafficking of memory Th cell precursors to the BM niches for memory Tʜ cells.

Additional information: Clone REA541 displays negligible binding to Fc receptors.

Alternative names

Itga2, gpIa, VLA-2α, VLA-2alpha, DX5

Detailed product information

Technical specifications

Clone
REA541
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody, human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
mouse
Antigen
CD49b
Molecular mass of antigen [kDa]
126
Distribution of antigen
NK cells, NKT cells, T helper cells
Entrez Gene ID
RRID
AB_2784228, AB_2784230, AB_2922145, AB_2658478, AB_2784229, AB_2752210, AB_2752212, AB_2658473, AB_2658477, AB_2658474, AB_2921818, AB_2905058

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for CD49b Antibody, anti-mouse, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support