CD11b Antibody, anti-human/mouse
Synonyms: ITGAM, CR3A, Mac-1 α, MAC1A, MO1A, SLEB6, integrin αM
EXTENDED VALIDATION
Bioz Star95/100 Bioz rating
239 Citations38 Images
Clone:
M1/70.15.11.5
Type of antibody:
Primary antibodies
Isotype:
rat IgG2bκ
Applications:
FC, MICS, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for CD11b Antibody, anti-human/mouse

Flow cytometry applications
APC
APC-Vio 770
Biotin
FITC
PE
PE-Vio 770
PerCP-Vio 700
VioBlue
VioGreen
pure
Species tested:
mouse
Recommended dilution:
1:50
Remark:
Cells should be stained prior to fixation, if formaldehyde is used as a fixative.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-113-793, 130-113-231
Description:
Mouse spleenocytes were stained with CD11b antibodies or with the corresponding isotype control antibodies (left images) and analyzed by flow cytometry using the MACSQuant® Analyzer. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application imageView details view details

Application imageView details view details
Species tested:
human
Recommended dilution:
1:50
Remark:
Cells should be stained prior to fixation, if formaldehyde is used as a fixative.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-113-793, 130-113-231
Description:
Human peripheral blood mononuclear cells (PBMCs) were stained with CD11b antibodies or with the corresponding isotype control antibodies (left images) and analyzed by flow cytometry using the MACSQuant® Analyzer. The Tandem Signal Enhancer has been used to increase binding specificity of tandem-dye–conjugated antibodies. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application imageView details view details

Application imageView details view details
MICS (MACSima Imaging Cyclic Staining) applications
APC
FITC
PE
Fixation:
frozen – PFA
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-113-793, 130-113-231
Testing grade:
Fixation:
frozen – Acetone
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-113-793, 130-113-231
Testing grade:
Extended validation for CD11b Antibody, anti-human/mouse
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with M1/70.15.11.5
M1/70
partial
ICRF44
low
CBRM1/5
low
REA713
low
Other clones
Overlap in epitope recognition with M1/70.15.11.5
M1/70
partial
REA592
high
ICRF44
low
CBRM1/5
low
REA713
low

Cells were incubated with an excess of purified unconjugated CD11b (M1/70.15.11.5) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Cells were incubated with an excess of purified unconjugated CD11b (M1/70.15.11.5) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD11b. Human peripheral blood cells (PBMCs) after erythrocyte lysis were stained with CD11b antibodies and plotted against the side scatter. As a control, CD11b antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD11b (M1/70.15.11.5). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD11b (M1/70.15.11.5). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for CD11b Antibody, anti-human/mouse
Overview

CD11b, also known as Mac-1 α or integrin αM chain, is part of the CD11b/CD18 heterodimer (Mac-1 α, Mβ2 integrin), also known as the C3 complement receptor. It functions as a receptor for complement (C3bi), fibrinogen, or clotting factor X. In humans, CD11b is strongly expressed on myeloid cells and weakly expressed on NK cells and some activated lymphocytes as well as on microglia in the brain. In mice, the CD11b antigen is expressed on monocytes/macrophages and microglia. To a lower extent it is expressed on granulocytes, NK cells, CD5+ B-1 cells, and subsets of dendritic cells. The monoclonal M1/70.15.11.5 antibody recognizes the human, mouse, and non-human primate CD11b antigen.

Alternative names

ITGAM, CR3A, Mac-1 α, MAC1A, MO1A, SLEB6, integrin αM

Detailed product information

Technical specifications

Clone
M1/70.15.11.5
Clonality
monoclonal
Isotype
rat IgG2bκ
Isotype control
Isotype Control Antibody, rat IgG2b
Host
rat
Type of antibody
Primary antibodies
Species reactivity
human, mouse, non-human primate
Cross-reactivity
rhesus monkey (Macaca mulatta), cynomolgus monkey (Macaca fascicularis)
Antigen
CD11b
Molecular mass of antigen [kDa]
125
Distribution of antigen
B cells, T cells, dendritic cells, granulocytes, monocytes, macrophages, NK cells
Entrez Gene ID
RRID
AB_2726043, AB_2726323, AB_2726317, AB_2726045, AB_2733024, AB_2726318, AB_2726320, AB_2733615, AB_2726047, AB_2727205, AB_2726046, AB_2726044, AB_2726321, AB_2726042, AB_2733023, AB_2726319, AB_2726322, AB_2726048, AB_2733614
Resources for CD11b Antibody, anti-human/mouse
Documents and Protocols
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support