Immunostaining and clearing of mouse brain hemispheres for 3D imaging analysis


This application protocol describes step-by-step the immunostaining and clearing of mouse brain hemispheres using the MACS® Clearing Kit for downstream 3D imaging analysis. The MACS Clearing Kit enables the immunostaining and clearing of up to 20 brain hemispheres from mice of any age.

Protocol

  • Always freshly prepare reagents. Failure to do so may lead to suboptimal results.

Preparation of PFA buffer

  • All steps that include paraformaldehyde (PFA) must be performed under a fume hood.
  • The protocol describes the preparation of 500 mL of 4% PFA buffer. For higher or lower volumes scale the amounts of the components accordingly.
  • Do not use ready-to-use PFA solutions.

  • Add 20 g of PFA powder to 400 mL of PBS and stir the mixture at 60 °C under a fume hood until it is dissolved.
    ▲ Note: Do not boil!
    ▲ Note: PFA powder does not dissolve instantly.
  • Add 0.2–0.4 g of NaOH and continue stirring at 60 °C until the solution clears up. This may take 2–3 hours.
  • Adjust the pH to 7.2–7.4 with HCl and NaOH.
  • Adjust the volume to 500 mL with PBS.
  • Filter the solution using a 0.22 µm filter.
  • Store PFA buffer at 4 °C for one week. For long-term storage prepare aliquots and store at –20 °C. Avoid repeated freeze/thaw cycles.

Preparation of 1× Antibody Staining Solution of the MACS® Clearing Kit

  • If precipitates occur due to storage of the 10× Antibody Staining Solution at low temperature, mix well before preparation of 1× Antibody Staining Solution.
  • 10× Antibody Staining Solution from the MACS Clearing Kit needs to be diluted 1:10 with sterile distilled water before use, e.g., by diluting 1 mL of 10× Antibody Staining Solution with 9 mL of sterile distilled water. Adjust the volume of 1× Antibody Staining Solution according to the number of samples to be cleared.
  • Always use freshly prepared 1× Antibody Staining Solution.

Preparation of ethanol/Tween® 20 dilutions for dehydration

  • The following solutions are needed:
    • Ethanol 30%/Tween® 20
    • Ethanol 50%/Tween® 20
    • Ethanol 70%/Tween® 20
    • Ethanol 90%/Tween® 20
    • Absolute (≥99.8%) ethanol/Tween® 20
  • Prepare within one or two days before use to ensure the absence of residual water.
  • Prepare absolute ethanol (≥99.8%) using activated molecular sieves (3Å; if the ethanol bottle is freshly opened, steps 1 to 7 are optional).
  • Prepare ethanol dilutions of 30%, 50%, 70%, and 90% in water. Use absolute ethanol (≥99.8%) and sterile distilled water to prepare the dilutions.

  • Cover the bottom of a heat-resistant glass petri dish with molecular sieves.
  • Heat molecular sieves in microwave at 750 W for 2 minutes.
  • Mix the sieves before heating again at 750 W for 2 minutes.
  • Repeat heating until no liquid vaporizes anymore and sieves are completely dry.
  • Let sieves cool down.
  • Transfer sieves into a bottle and add absolute ethanol.
  • Incubate the sieves for 1–2 days to absorb residual water.
  • Filter the needed volume of absolute ethanol from the previous step using a 0.22 µm filter and use sterile distilled water to make the respective (30%, 50%, 70%, 90%) dilutions.
  • Add Tween® 20 to each dilution to a final concentration of 2% (v/v).

Preparation of Clearing Solution from the MACS Clearing Kit

  • Clearing Solution is ready-to-use, but may freeze when stored at 2–8 °C. Therefore, it is recommended to prepare aliquots and store at 2–8 °C. Bring aliquots to room temperature (20–25 °C) before proceeding to clearing of samples.
    ▲ Note:
    Use polypropylene tubes for preparation of aliquots. Other plastics might not be compatible with the Clearing Solution.

Shop required products for this application protocol

3 products found

|