Central Innovation Programme for SMEs (ZIM)

Note: The project descriptions reflect the status and objectives of the projects at their initial stage.

RETI-IM

Retinal imaging techniques for early diagnosis of neurodegenerative and neuroimmunological diseases

Project duration: May 2014 – October 2016

Project goal: A key challenge in investigating the causes of neuro-immunological diseases is to observe and understand dynamic, immune-mediated damage processes directly in the brain. Since the brain is inaccessible to high-resolution imaging techniques through the skull, direct observation is not yet possible. With the eye, there is a possible but technically challenging access to the brain: the retina is formed from brain tissue and contains brain-specific cell types such as neurons. Many neurodegenerative diseases (e.g. MS) lead to specific changes at the retina.

Approach: The aim of this project was to develop an in vivo microscopy technique that can image functional and morphological properties of the retina with sub-cellular resolution. Here, a prototype for use in animal models was developed. For the pharmaceutical industry, such a technology would be ground-breaking for the understanding of neuro-immunological processes. Applied in therapy research, new dynamic immune processes could be identified and the findings used to develop specific active substances.

Project coordinator

CountryCityInstitution
DEBielefeldLaVision BioTec (now Miltenyi Biotec B.V. & Co. KG)

Project partner(s)

CountryCityInstitution
DEBerlinCharité, Universitätsmedizin Berlin
DEPlaneggMenlo Systems GmbH
DERatingenLuigs und Neumann GmbH
DELübeckMedizinisches Laserzentrum Lübeck GmbH
DEJenaInstitut für Photonische Technologien e.V.
DEBerlinDeutsches Rheuma-Forschungszentrum

HD-DET

Highly dynamic detector electronics for laser scanning microscopy and time-of-flight spectrograph

Project duration: May 2013 – April 2015

Project goal: The aim of the project was to develop highly dynamic detector electronics for the readout of photonic detectors, ultrafast processing of pulses and time-dependent control of mass spectrographs. Among other things, highly dynamic means that very low-light and very high-light signals can be recorded and displayed simultaneously in one image.

Approach: The targeted improvement factor of 500 in image dynamics was achieved by using two methods simultaneously: Strong light signals were processed by a conventional mixed-signal chain (sensor element->amplifier->analog-to-digital converter), while weak signals were detected by a high-speed digital photon counter. In the limit between weak and strong signals, both the discrete photon counts and the digitally-converted continuous output current of a physical sensing element were then used to generate the real-time microscopy images.

Project coordinator

CountryCityInstitution
DEBielefeldLaVision BioTec (now Miltenyi Biotec B.V. & Co. KG)

Project partner(s)

CountryCityInstitution
DEMainzSurface Concept GmbH
DEBielefeldUniversität Bielefeld, AG Biomolekulare Photonik
DEBielefeldUniversität Bielefeld, AG Kognitronik & Sensorik

CSIM

Confocal sheet-illumination microscope for the investigation of dynamic processes in living tissue

Project duration: February 2012 – May 2014

Project goal: Human brain functions such as memory storage and retrieval are the result of interactions between neurons. In order to decipher the function of individual cells or cellular networks, they must be studied in their natural environment. The goal of research is to understand how the neuronal network functions and to decipher the "neuronal code" in order to ultimately gain crucial insights into diseases of the nervous system (e.g. Alzheimer's, Parkinson's, epilepsies).

Approach: Within the scope of this project, a sample-friendly, three-dimensional high-resolution microscopy technique for the observation of dynamic processes in living tissue was therefore developed, applicable also in immunology and developmental biology. In addition to high selectivity and sensitivity, the acquisition of up to 500 images per second were possible. The tasks included the development of the scan head and the detection unit, the laser scanning illumination lens, the measurement system including automation of the measurement sequences, the image processing software and the sample holders for different applications.

With the development and market launch of the light sheet microscope, which was developed within the CSIM project, LaVision BioTec* was awarded a prize from the Central Innovation Programme for SMEs (ZIM) of the BMWi.

Project coordinator

CountryCityInstitution
DEBielefeldLaVision BioTec (now Miltenyi Biotec B.V. & Co. KG)

Project partner(s)

CountryCityInstitution
DEJenaGrintech GmbH
DEBonnRheinische Friedrich-Wilhelms-Universität Bonn, Universitätsklinik für Epileptologie, Labor für Experimentelle Epileptologie
DEMünsterWestfälische Wilhelms-Universität-Münster, Institut für Informatik
DEBonnDeutsches Zentrum für Neurodegenerative Erkrankungen (DZNE) Bonn, Neuronal Substrates of Cognitive Dysfunction, Helmholtz-Gemeinschaft
DEMünsterMax-Planck-Institut für molekulare Biomedizin Münster, Abteilung vaskuläre Zellbiologie, Signalübertragung in Säugerzellen

*LaVision BioTec was acquired by Miltenyi Biotec in 2018. As of September 2023, LaVision BioTec GmbH is operating as Miltenyi Biotec B.V. & Co. KG.

Partner with us

Are you looking for a reliable partner for your next grant project?

Get in touch with our Grant Management Team to discuss your ideas.