Cookie Settings
We use cookies to provide the best possible website experience for you. This includes cookies that are technically required to ensure a proper functioning of the website, as well as cookies which are used solely for anonymous statistical purposes, for more comfortable website settings, or for displaying personalized content. You are free to choose the categories you would like to permit. Please note that depending on your settings, the full functionality of the website may no longer be available. Further information can be found in our Privacy Statement and Cookie Statement.
Naive CD4 + T cells were isolated from a single-cell suspension from mouse spleen using the Naive CD4 + T Cell Isolation Kit, an LS Column, and a MidiMACS™ Separator. Cells were fluorescently stained with CD45-VioGreen (# 130-102-412) CD4-VioBlue® (# 130-102-456), CD62L-PE (# 130-102-543), CD3ε-APC-Vio770™ (# 130-102-306), and CD44-FITC (# 130-102-511) and analyzed by flow cytometry using the MACSQuant ® Analyzer. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence and a gate was set on CD45 + cells. |
Before separation |
Unseparated fraction | Gated on CD45 + CD3ε + CD4 + T cells |
Naive CD4 + T Cell Isolation Kit | Naive CD4 + T Cell Isolation Kit |
Isolated naive CD4+ T cells |
Isolated naive CD4 + cells | Gated on CD45 + CD3ε + CD4 + T cells |
Naive CD4 + T Cell Isolation Kit | Naive CD4 + T Cell Isolation Kit |
For a CD4 T cell lab, we use a lot of these kits. We've tried others, but this has always come out on top for quality.
Naive CD4 + T cells were isolated from a single-cell suspension from mouse spleen using the Naive CD4 + T Cell Isolation Kit, an LS Column, and a MidiMACS™ Separator. Cells were fluorescently stained with CD45-VioGreen (# 130-102-412) CD4-VioBlue® (# 130-102-456), CD62L-PE (# 130-102-543), CD3ε-APC-Vio770™ (# 130-102-306), and CD44-FITC (# 130-102-511) and analyzed by flow cytometry using the MACSQuant ® Analyzer. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence and a gate was set on CD45 + cells. |
Before separation |
Unseparated fraction | Gated on CD45 + CD3ε + CD4 + T cells |
Naive CD4 + T Cell Isolation Kit | Naive CD4 + T Cell Isolation Kit |
Isolated naive CD4+ T cells |
Isolated naive CD4 + cells | Gated on CD45 + CD3ε + CD4 + T cells |
Naive CD4 + T Cell Isolation Kit | Naive CD4 + T Cell Isolation Kit |
For a CD4 T cell lab, we use a lot of these kits. We've tried others, but this has always come out on top for quality.
Seems like you are coming from USA!
Do you want to visit our website in your country?
Copyright © 2023 Miltenyi Biotec and/or its affiliates. All rights reserved.