PE-Vio® 615 Fluorophore

PE-Vio 615 for blue or yellow lasers

PE-Vio 615 is a bright tandem dye optimally excited by blue and yellow lasers, providing maximum flexibility for panel design. Its superior brightness makes it ideal for detecting low-expressing markers, while minimal spillover ensures clean results and better resolution of the cell populations.

Fluorophore at one glance

LaserBlue (488 nm) or yellow (561 nm)
Absorption max.565 nm
Emission max.619 nm
ApplicationFlow cytometry, microscopy
Common filter set (FC)655–730 nm or 615/20 nm
Stain index3 out of 5
Fixation stabilityPFA

Logo of the VioDyes, fluorochromes for flow cytometry and fluorescence microscopy high fluorescence characterized by intensities and low spillover

PE-Vio 615 is a superior alternative to:

  • ECD
  • PE-Texas-Red®
  • PE eFluor® 610
  • PE CF594
  • PE/Dazzle™ 594

Characteristics of PE-Vio 615

Line charts showing excitation (A) and emission (B) spectra of PE-Vio 615 and related fluorochromes from other providers.

Adsorption and emission spectra of PE-Vio 615

  • Tandem dye composition: Uses PE as the donor and Vio 615 as the acceptor dye.
  • Maximum brightness: Best performance achieved with yellow lasers (e.g., MACSQuant® VYB).
  • Instrument compatibility: PE shows peak excitation at 496 nm and 565 nm, enabling optimal excitation by blue, green, and yellow lasers (488–561 nm). Emission can be captured using filters designed for PE-Texas Red, such as a 615/20 nm filter.

Dot plots from flow cytometry analysis on PBMCs stained with CD4-PE-Vio 615 using the MACSQuant VYB and MACSQuant 10, showing instrument compatibility.

Absorption and emission maxima of fluorochromes related to PE-Vio 615.

FluorochromeAbsorption max. (nm)Emission max. (nm)
PE-Vio 615565619
ECD, PE-Texas Red565613
PE-eFluor 610565606
PE-CF594565614
PE/Dazzle 594565612

Histogram showing the mean fluorescence intensity (MFI) of CD4 conjugated with PE-Vio 615 and similar dyes from other providers.

Brighter and clearer staining

  • Bright alternative to PE-eFluor, PE-CF594, and ECD.
  • High mean fluorescence intensity (MFI) and stain index (SI) enable clear distinction of positive and negative cell populations.

Flow cytometric analysis of human PBMCs stained with CD56 antibodies (clone REA196) conjugated to either PE-Vio 615 or PE and with a CD335-Vio Bright FITC antibody
Flow cytometric analysis of human PBMCs stained with CD56 antibodies (clone REA196) conjugated to PE, PE-Vio 615, or PE-Dazzle 594 and with CD335-Vio Bright FITC

Excellent performance after paraformaldehyde fixation

  • Tandem dyes are often sensitive to fixation, yet stability is essential for flow cytometry protocols involving fixed dyes.
  • Excellent stability to paraformaldehyde without an increase in background signal, making it ideal for fixation-dependent workflows.

Resources

Fluorescence spectra viewer

Analyze the spectral signatures of your fluorochromes to avoid spillover.

Top view on antibody vials with color-coded lids placed in rows

Multicolor flow cytometry panel builder

Design complex multicolor panels with optimized antibody choices, tailored to your experimental setup.