HLA Class I Bw6 Antibody, anti-human, REAfinity™
Synonyms: HLA-B, AS, SPDA1
RECOMBINANT EXTENDED VALIDATION
Bioz Star94/100 Bioz rating
14 Citations2 Images
Clone:
REA143 | Anti Bw6
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
FC, MICS, IF, IHC, MC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for HLA Class I Bw6 Antibody, anti-human, REAfinity™

Flow cytometry applications
APC
APC-Vio 770
Biotin
FITC
PE
PE-Vio 615
PE-Vio 670
PE-Vio 770
PerCP-Vio 700
Vio Bright B515
Vio Bright R720
Vio Bright V600
Vio Bright V646
VioBlue
VioGreen
Species tested:
human
Recommended dilution:
1:50
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-136-543, 130-136-643
Description:
Human peripheral blood cells after erythrocyte lysis were stained with Anti-HLA Class I Bw6 antibodies as well as with CD4 antibodies and anlyzed by flow cytometry using the MACSQuant® Analyzer. The specificity of the conjugated antibodies was confirmed by blocking the binding to the ligand, using pure unconjugated antibodies (left image). The Tandem Signal Enhancer has been used to increase binding specificity of tandem-dye–conjugated antibodies. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application imageView details view details

Application imageView details view details
MICS (MACSima Imaging Cyclic Staining) applications
APC
FITC
PE
Fixation:
frozen – Acetone
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-136-543, 130-136-643
Testing grade:
Fixation:
frozen – PFA
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-136-543, 130-136-643
Testing grade:
Mass cytometry applications
pure
Conjugate:
pure
Used products:
130-124-530
Extended validation for HLA Class I Bw6 Antibody, anti-human, REAfinity™
Specificity
Knockout validation

To ensure antibody specificity, the target gene is knocked out in a suitable cell line using the CRISPR/Cas9 system and the knockout is confirmed by sequencing of the target locus. The antibody is considered to bind specifically to the intended epitope if no antibody binding to the knockout cells can be detected. The antibody staining is controlled by fluorescence microscopy and/or flow cytometry.

WT
Extended-Validation detailed information image
KO
Extended-Validation detailed information image

Fluorescence microscopy image of HLA Class I Bw6 knockout cells. Wild type (WT, left) and knockout cells (KO, right) were stained with HLA Class I Bw6-PE (REA143, red) and counterstained with DRAQ5 (blue) as DNA stain.

Extended-Validation detailed information image

Overlay histogram showing flow cytometric analysis of HLA Class I Bw6 knockout cells. Wild type (red) and knockout cells (blue) were stained with HLA Class I Bw6-PE, clone (REA143). Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells and cell doublets were excluded from the analysis based on scatter signals and propidium iodide fluorescence.

Sensitivity
Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using HLA Class I Bw6 (REA143). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for HLA Class I Bw6 Antibody, anti-human, REAfinity™
Overview

Clone REA143 recognizes HLA Bw6, a class I human leukocyte antigen (HLA). Expressed on the surface of most nucleated cells, class I molecules are heterodimeric molecules and consist of a type I integral membrane α heavy chain and soluble β2 microglobulin protein. The extracellular region of the heavy chain further consists of 3 domains, of which one comprises the peptide binding groove. Antigens binding to class I molecules are 8–10 amino acids long and play an important role in recognition of the virus infected and malignant cells by cytotoxic T lymphocytes (CTLs). In addition, class I molecules interact with NK cell receptors to modulate the activity of NK cells. Downregulation of HLA class I Bw6 allele has been reported in leukemic patients where it is suggested that via this downregulation, leukemic cells may circumvent attack by CTLs.

Additional information: Clone REA143 displays negligible binding to Fc receptors.

Alternative names

HLA-B, AS, SPDA1

Detailed product information

Technical specifications

Clone
REA143
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody (S), human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
human
Antigen
HLA Class I Bw6
Molecular mass of antigen [kDa]
32
Entrez Gene ID
RRID
AB_2819663, AB_2905245, AB_2905244, AB_2905243, AB_2652031, AB_2652035, AB_2652036, AB_2928683, AB_2928682, AB_2922088, AB_2922055, AB_2819475, AB_2819460, AB_2652032, AB_2905241, AB_2905246, AB_2905242, AB_2652027, AB_2652028, AB_2652038, AB_2652037, AB_2652029, AB_2652030

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for HLA Class I Bw6 Antibody, anti-human, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support