- Clone:
- T6D11
- Type of antibody:
- Primary antibodies
- Isotype:
- mouse IgG2b
- Applications:
- FC, MICS, IF, IHC, MC Glossary
- Select a conjugate:
- Select a size:
Related products for CD45RA Antibody, anti-human
In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.
Cells were incubated with an excess of purified unconjugated CD45RA (T6D11) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.
To ensure antibody specificity, the target gene is knocked out in a suitable cell line using the CRISPR/Cas9 system and the knockout is confirmed by sequencing of the target locus. The antibody is considered to bind specifically to the intended epitope if no antibody binding to the knockout cells can be detected. The antibody staining is controlled by fluorescence microscopy and/or flow cytometry.
Fluorescence microscopy image of CD45RA knockout cells. Wild type (WT, left) and knockout cells (KO, right) were stained with CD45RA-PE (T6D11, red) and counterstained with DRAQ5 (blue) as DNA stain.
Overlay histogram showing flow cytometric analysis of CD45RA knockout cells. Wild type (red) and knockout cells (blue) were stained with CD45RA-PE, clone (T6D11). Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells and cell doublets were excluded from the analysis based on scatter signals and propidium iodide fluorescence.
Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.
Flow cytometric comparison of different clones for CD45RA. Human peripheral blood mononuclear cells (PBMCs) were stained with CD45RA antibodies and with a suitable counterstaining. As a control, CD45RA antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.
To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.
Comparison of staining pattern on non-fixed and fixed cells using CD45RA (T6D11). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.
Clone T6D11 recognizes the human CD45RA antigen which is expressed on naive CD4+ and CD8+ T cells as well as on CD8+ effector T cells. CD45RA is also present on subsets of B and NK cells as well as on plasmacytoid dendritic cells. The CD45RA antibody recognizes the 220 kDa isoform of the leukocyte common antigen (LCA), a transmembrane tyrosine phosphatase.
Ptprc, B220, CD45, CD45R, GP180, L-CA, LY5, T200
Technical specifications
To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.
Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.