CD172a (SIRPα) Antibody, anti-human, REAfinity™
Synonyms: SIRPα, Bit, Mfr, MYD-1, P84, Ptpns1, SHPS-1, Sirp
RECOMBINANT EXTENDED VALIDATION
Bioz Star92/100 Bioz rating
14 Citations3 Images
Clone:
REA144 | SE5A5
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
FC, MC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for CD172a (SIRPα) Antibody, anti-human, REAfinity™

Flow cytometry applications
APC
APC-Vio 770
Biotin
FITC
PE
PE-Vio 615
PE-Vio 770
PerCP-Vio 700
Vio Bright R720
Recommended dilution:
1:50
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-133-388, 130-133-369
Description:
Human peripheral blood granulocytes were stained with CD172a (SIRPα) antibodies and analyzed by flow cytometry using the MACSQuant® Analyzer. The specificity of the conjugated antibodies was confirmed by blocking the binding to the ligand, using pure unconjugated antibodies (left peak). Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application image
Mass cytometry applications
pure
Conjugate:
pure
Used products:
130-122-330
Extended validation for CD172a (SIRPα) Antibody, anti-human, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA144
15-414
low
148
partial
SE5A5
partial

Cells were incubated with an excess of purified unconjugated CD172a (SIRPα) (REA144) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD172a (SIRPα). Human peripheral blood granulocytes were stained with CD172a (SIRPα) antibodies and with a suitable counterstaining. As a control, CD172a (SIRPα) antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD172a (SIRPa) shown as histograms

Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD172a (SIRPα) (REA144). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD172a (SIRPα) (REA144). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for CD172a (SIRPα) Antibody, anti-human, REAfinity™
Overview

Clone REA144 recognizes CD172a, which is also known as signal regulatory protein α (SIRPα). CD172a belongs to the Ig superfamily and is 75–110 kDa single-pass type I regulatory membrane protein. Expression of CD172a is found primarily on hematopoietic stem cells, neurons, and myeloid cells such as macrophages, monocytes, dendritic cells, granulocytes, and myeloid progenitors. CD172a phosphorylated at intracellular tyrosine sites, in response to extracellular stimuli, serves as the docking site for phosphatases such as SHP-1, SHP-2, or SHIP, which inturn desphosphorylate molecules involved in regulating various physiological effects. CD47 has been suggested as a ligand of CD172a.

Additional information: Clone REA144 displays negligible binding to Fc receptors.

Alternative names

SIRPα, Bit, Mfr, MYD-1, P84, Ptpns1, SHPS-1, Sirp

Detailed product information

Technical specifications

Clone
REA144
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody (S), human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
human
Antigen
CD172a (SIRPα)
Molecular mass of antigen [kDa]
52
Distribution of antigen
macrophages, dendritic cells, monocytes, neurons, stem cells, granulocytes, hematopoietic stem and progenitor cells
Entrez Gene ID
RRID
AB_2801815, AB_2922052, AB_2801909, AB_2922085, AB_2655599, AB_2655600, AB_2655609, AB_2655610, AB_2811495, AB_2904781, AB_2904782, AB_2904784, AB_2904783, AB_2811491, AB_2801813

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for CD172a (SIRPα) Antibody, anti-human, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support