CD95 (FAS) Antibody, anti-mouse, REAfinity™
Synonyms: FAS, APO-1, Apt1, Tnfrsf6, TNFR6, lpr
RECOMBINANT EXTENDED VALIDATION
Bioz Star94/100 Bioz rating
12 Citations
Clone:
REA453 | Jo2
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
FC, MICS, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:

Related products for CD95 (FAS) Antibody, anti-mouse, REAfinity™

Flow cytometry applications
APC
Biotin
PE
PE-Vio 770
Vio Bright FITC
Recommended dilution:
1:50
Remark:
Cells should be stained prior to fixation, if formaldehyde is used as a fixative.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-123-568
Description:
Thymocytes from BALB/c mice were stained with CD95 (FAS) antibodies or with the corresponding REA Control antibodies (left images) as well as with CD8a antibodies. Flow cytometry was performed using the MACSQuant® Analyzer. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence.

Application imageView details view details

Application imageView details view details
MICS (MACSima Imaging Cyclic Staining) applications
APC
PE
Fixation:
frozen – Acetone
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-123-568
Testing grade:
Extended validation for CD95 (FAS) Antibody, anti-mouse, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA453
Jo2
high
SA367H8
low

Cells were incubated with an excess of purified unconjugated CD95 (FAS) (REA453) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD95 (FAS) (specificity from PIM). Thymocytes from BALB/c mice were stained with CD95 (FAS) (specificity from PIM) antibodies and with a suitable counterstaining. As a control, CD95 (FAS) antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. The recommended titers of respective antibodies from different suppliers were used.

Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD95 shown as histograms

Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD95 (FAS) (REA453). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for CD95 (FAS) Antibody, anti-mouse, REAfinity™
Overview

Clone REA453 recognizes the mouse CD95 antigen, a single-pass type I membrane protein which is also known as FAS or Apo-1. CD95 is a member of the tumor necrosis factor receptor superfamily and is found on the surface of many normal and neoplastically transformed cells. It is an apoptosis-inducing death receptor that regulates tissue homeostasis mainly in the immune system through induction of apoptosis by binding of its ligand CD95L (FASL/Apo-1L). CD95 and CD95L are up-regulated on lymphocytes upon activation and are known to play a key role in the regulation of an inflammatory response. CD95 also plays an apoptosis-independent role in non-immune cells and it has been implicated in cancer cell growth, migration, and tumor progression. During cancer progression CD95 is frequently down regulated or cells are rendered apoptosis resistant raising the possibility that loss of CD95 is part of a mechanism for tumor evasion.

Additional information: Clone REA453 displays negligible binding to Fc receptors.

Alternative names

FAS, APO-1, Apt1, Tnfrsf6, TNFR6, lpr

Detailed product information

Technical specifications

Clone
REA453
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody, human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
mouse
Antigen
CD95 (FAS)
Molecular mass of antigen [kDa]
35
Distribution of antigen
lymphocytes
Entrez Gene ID
RRID
AB_2889640, AB_2659654, AB_2659655, AB_2801758, AB_2889639, AB_2751726, AB_2751784

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for CD95 (FAS) Antibody, anti-mouse, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support