CD178 Antibody, anti-mouse, REAfinity™
Synonyms: FasL, APT1LG1, CD95L, TNFSF6, gld
RECOMBINANT EXTENDED VALIDATION
Bioz Star92/100 Bioz rating
2 Citations
Clone:
REA1171 | MFL3
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
FC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for CD178 Antibody, anti-mouse, REAfinity™

Flow cytometry applications
Biotin
PE
PE-Vio 615
PE-Vio 770
Vio Bright B515
Recommended dilution:
1:50
Remark:
Cells should be stained prior to fixation, if formaldehyde is used as a fixative.
Data source:
Miltenyi Biotec
Conjugate:
Biotin
Used products:
130-120-926, 130-120-932
Description:
A mixture of L5178Y cells and cells from thymus was stained with CD178 antibodies or with the corresponding REA Control antibodies (left peak) and analyzed by flow cytometry using the MACSQuant® Analyzer. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application image
Extended validation for CD178 Antibody, anti-mouse, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA1171
MFL3
high
Kay-10
high
A19116F
partial
MFL-3
high

Cells were incubated with an excess of purified unconjugated CD178 (REA1171) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD178 (REA1171). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for CD178 Antibody, anti-mouse, REAfinity™
Overview

Clone REA1171 recognizes the type II transmembrane glycoprotein mouse CD178, also known as Fas Ligand, FasL, or CD95 Ligand, which is a 40 kDa member of the TNF cytokine family expressed on activated lymphocytes such as T cells, NK cells, or monocytes as well as in immune-privilaged sites, e.g, cornea or testis. CD178 can trigger apoptosis through trimerization of the Fas receptor CD95. Thereby, CD178 and CD95 play a key role in the regulation of the immune system. Cleavage of membrane bound CD178 from the cell surface via matrix metalloproteinases (such as MMP-7) generates soluble CD178 molecules.

Additional information: Clone REA1171 displays negligible binding to Fc receptors.

Alternative names

FasL, APT1LG1, CD95L, TNFSF6, gld

Detailed product information

Technical specifications

Clone
REA1171
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody, human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
mouse
Antigen
CD178
Molecular mass of antigen [kDa]
31
Distribution of antigen
monocytes, NK cells, T cells
Entrez Gene ID
RRID
AB_2784008, AB_2784016, AB_2784017, AB_2784011, AB_2784009, AB_2784010, AB_2784014, AB_2784015, AB_2784012, AB_2784013

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for CD178 Antibody, anti-mouse, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support