Bcl-6 Antibody, anti-human/mouse, REAfinity™
Synonyms: BCL6, BCL5, BCL6A, LAZ3, ZBTB27, ZNF51
RECOMBINANT EXTENDED VALIDATION
Bioz Star94/100 Bioz rating
9 Citations2 Images
Clone:
REA373 | 7D1
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
ICFC, MICS, IF, IHC, MC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for Bcl-6 Antibody, anti-human/mouse, REAfinity™

Intracellular flow cytometry applications
APC
PE
Recommended dilution:
1:50
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-121-997, 130-122-013
Description:
Human Ramos cells were fixed and permeabilized using the FoxP3 Staining Buffer Set. Cells were then stained with Anti-Bcl-6 antibodies or with the corresponding REA Control (I) antibodies (left peak) and analyzed with the MACSQuant® Analyzer. Cell debris were excluded from the analysis based on scatter signals.

Application image
MICS (MACSima Imaging Cyclic Staining) applications
APC
PE
Fixation:
frozen – Acetone
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-121-997, 130-122-013
Testing grade:
Mass cytometry applications
pure
Conjugate:
pure
Used products:
130-124-533
Extended validation for Bcl-6 Antibody, anti-human/mouse, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA373
BCL-DWN
low
K112-91
low
7D-1
high
IG-191E/A8
low
BCL-UP
low

Cells were incubated with an excess of purified unconjugated Bcl-6 (REA373) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Specifications for Bcl-6 Antibody, anti-human/mouse, REAfinity™
Overview

Clone REA373 recognizes the human and mouse Bcl-6 antigen, a member of the BTB-zinc finger family of proteins. Bcl-6 is a transcriptional repressor, expressed in germinal center T and B cells and in primary immature dendritic cells. It plays critical functions in various cell types within the adaptive and innate compartments of the immune system. Bcl-6 is highly up-regulated in B cells after T cell–dependent antigenic challenge, and is required for formation of germinal centers within which B cells undergo immunoglobulin affinity maturation. It also plays an important role in macrophages, where it mediates a dampening effect on inflammatory signaling through repression of chemokine expression and NF-κB target genes.

Additional information: Clone REA373 displays negligible binding to Fc receptors.

Alternative names

BCL6, BCL5, BCL6A, LAZ3, ZBTB27, ZNF51

Detailed product information

Technical specifications

Clone
REA373
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody (I), human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
human, mouse
Antigen
Bcl-6
Molecular mass of antigen [kDa]
79
Distribution of antigen
B cells, T cells
Entrez Gene ID
RRID
AB_2819665, AB_2801827, AB_2801712, AB_2801714, AB_2801823

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for Bcl-6 Antibody, anti-human/mouse, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support