Immunostaining and clearing of organoids and spheroids for 3D imaging analysis


This application protocol describes step-by-step the immunostaining and clearing of organoids and spheroids using the MACS® Clearing Kit for downstream 3D imaging analysis. The MACS Clearing Kit enables the immunostaining and clearing of up to 60 samples of <2 mm in diameter.

▲ Note: If using the MACS® Deep Clearing Kit (order no. 130-136-470), preliminary assessment suggests it is compatible with this protocol, using the corresponding solutions and incubation times. For best results, user-side optimization may be necessary.

Please substitute: Deep Antibody Staining Solution (8x) for 10x Antibody Staining Solution, Deep Permeabilization Solution for Permeabilization Solution, Deep Clearing Solution for Clearing Solution

Protocol

  • Always freshly prepare reagents. Failure to do so may lead to suboptimal results.

Preparation of PFA buffer

  • All steps that include paraformaldehyde (PFA) must be performed under a fume hood.
  • The protocol describes the preparation of 500 mL of 4% PFA buffer. For higher or lower volumes scale the amounts of the components accordingly.
  • Do not use ready-to-use PFA solutions.

  • Add 20 g of PFA powder to 400 mL of PBS and stir the mixture at 60 °C under a fume hood until it is dissolved
    ▲ Note: Do not boil!
    ▲ Note: PFA powder does not dissolve instantly.
  • Add 0.2–0.4 g of NaOH and continue stirring at 60 °C until the solution clears up. This may take 2–3 hours.
  • Adjust the pH to 7.2–7.4 with HCl and NaOH.
  • Adjust the volume to 500 mL with PBS.
  • Filter the solution using a 0.22 µm filter.
  • PFA buffer can be stored at 4 °C for one week. For long-term storage prepare aliquots and store at – 20 °C. Avoid repeated freeze/thaw cycles.

Preparation of 1× Antibody Staining Solution

  • If precipitation occurs due to storage of the 10× Antibody Staining Solution at low temperature, mix well before preparation of 1× Antibody Staining Solution.
  • 10× Antibody Staining Solution needs to be diluted 1:10 with sterile distilled water before use, e.g., by diluting 1 mL of 10× Antibody Staining Solution with 9 mL of sterile distilled water. Adjust the volume of 1× Antibody Staining Solution according to the number of samples to be cleared.
    ▲ Note: When using MACS Deep Clearing Kit, Deep Antibody Staining Solution (8×) needs to be diluted 1:8 with PBS before use. Prepare Deep Antibody Staining Solution (1×) by diluting 1 mL of Deep Antibody Staining Solution (8×) with 7 mL of PBS. Adjust the volume of Deep Antibody Staining Solution (1×) to the amount of tissue to be cleared.
  • Always use freshly prepared diluted 1× Antibody Staining Solution.

Preparation of ethanol/Tween® 20 dilutions for dehydration

  • The following solutions are needed:
    • Ethanol 50%/Tween® 20
    • Ethanol 70%/Tween® 20
    • Absolute (≥99.8%) ethanol/Tween® 20
  • Prepare ethanol dilutions of 50% and 70% in water. Use absolute ethanol (≥99.8%) and sterile distilled water to prepare the dilutions. Add Tween® 20 to each dilution for a final concentration of 2%.
    ▲ Note: Make sure to use fresh absolute ethanol (≥99.8%) that does not contain water residues.

Preparation of Clearing Solution

  • Clearing Solution is ready-to-use, but may freeze when stored at 2–8 °C. Therefore, it is recommended to prepare aliquots and store at 2–8 °C. Take out aliquots to room temperature (20– 25 °C) before proceeding to clearing of samples.
    ▲ Note:
    Use polypropylene tubes for preparation of aliquots. Other plastics might not be compatible with the Clearing Solution.

Shop required products for this application protocol

3 products found

|