| Optics | |
| Laser excitation | 405 nm, 100 mW 488 nm, 100 mW 638 nm, 100 mW |
| Emission detectors | V1: 450/50 nm V2: 525/50 nm B1: 525/50 nm B2: 585/40 nm B3: 655–730 nm B4: 750 nm LP R1: 655–730 nm R2: 750 nm LP Backscatter and side scatter for detection of size & granularity of cells |
| Fluorescence performance | 5 decade logarithmic scales, display in lin, log, or hlog scales |
| Performance | |
| Purity | >99%* |
| Cell flow rate | Up to 55,000 cells/s for the MACSQuant Tyto Cartridge and up to 110,000 cells/s for the MACSQuant Tyto Cartridge HS |
| Sort rate | Up to 30,000 valve actuations/s |
| Viability | >99% for lymphocytes* |
| Sorting mode | Two-way sorting of sorted and non-sorted cells |
| Technical support | Built-in live support functionality for reliable support in real time |
| Operating pressure | <230 mbar (3 psi) with the MACSQuant Tyto Cartridge and 1100 mbar (<14 psi) with the MACSQuant Tyto Cartridge HS |
| Temperature control range | 4–25 °C (under standard environmental conditions) |
| Carry-over | No sample-to-sample carry-over due to single-use disposable cartridge |
| Data management | |
| Measurement parameters | Height & Area measurements for all parameters |
| Signal processing | 16-bit analog-to-digital conversion and signal processing |
| Operating system | Core i7, 512 GB flash disk, 8 GB DDR4 RAM and Windows® 7 64-bit |
| Compensation | Full 8×8 matrix compensation |
| Data files | .mqd (proprietary file type); fcs (2.0, 3.0, 3.1 compatible) |
| Operation details | |
| Dimensions | 965 × 585 × 280 mm3: without external monitor 965 × 585 × 760 mm3: with external monitor |
| Weight | 62 kg (137 lbs): without external monitor 67 kg (148 lbs): with external monitor |
| Monitors | 32 ̎ display and 15.6 ̎ touchscreen (internal) |
| Power requirements / consumption | 100-240 V, 50/60 Hz / 300 W: without external monitor 100-240 V, 50/60 Hz / 500 W: with external monitor |
| Ports | 4× USB 2.0, 6× USB 3.0, 2× Ethernet, DVI-D |
| Environmental conditions | |
| Operational temperature / humidity | 18–25 °C / 0–85% relative humidity, non-condensating |
| Emission sound pressure < 70 dB(A) level at workstation | <70 dB(A) |
| Cartridge details | |
| Sterility | Ethylene oxide-validated sterilization method to guarantee sterility of each cartridge |
| A-septic filters | 0.1 µm hydrophobic filters at air inlet and outlet ports |
| Sorting channel width | 25 × 50 µm |
| Maximum loading volume (input) | 100 µL–10 mL |
| Maximum loading cell number | 5×107 cells/mL |
| Cartridge alignment for laser positioning | Continuous automated cartridge alignment also during the sort |
| Cell retrieval | No cell loss - negatively sorted cells are kept in the negative collection chamber |
| Barcode labeling | Cartridges are labeled with a barcode for easy identification and traceability |
*dependent on input sample and Poisson statistics