Isolation and analysis of macrophages and myeloid-derived suppressor cells (MDSCs)

  • Gentle dissociation with preserved cellular and tissue integrity
  • Isolation and analysis of macrophages and MDSCs

Application protocols

Discover our workflows for macrophages and MDCSs and find the one that fits your experimental needs.

Macrophages and MDSCs application tools and data by workflow step

Dissociation of mouse spleen tissue

Mouse macrophages are extensively studied in tissue and tumor samples. For reliable isolation of mouse macrophages, gentle dissociation of lymphoid tissue is key. Mouse spleen can be dissociated into single-cell suspensions using our Spleen Dissociation Kit, mouse in combination with our gentleMACS™ Dissociator with Heaters. Mechanical dissociation with enzymatic degradation of the extracellular matrix maintains the structural integrity of tissues.

video preview Play video

Video
Dissociation of mouse spleen tissue with the gentleMACS™ Dissociator

Watch how simple it is to dissociate mouse spleen tissue with the gentleMACS Dissociator.

Detection of human myeloid-MDSCs

The MDSC Detection Kit has been developed to allow standardized and simplified flow cytometric analysis of subpopulations of MDSCs described so far. For greater flexibility, the product configuration also allows extension of the analysis panel with additional specificities of interest (e.g. CD10, CD66b, CD15, and LOX-1).

 

MDSC Detection Kit, human

A) Gating strategy

All events
Gated on R1
Gated on R2
Gated on R3

B) Identification of low density PMN cells (PMN-MDSCs) 

Gated on R4
Gated on R5

C) Identification of M-MDSCs:

Gated on R6
Gated on R6

D) Identification of e-MDSCs:

Gated on R7
Gated on R7

Human PBMCs were stained using the MDSC Detection Kit, human and analyzed by flow cytometry using the MACSQuant®Analyzer 10. A) To exclude red blood cells and identify leukocytes, a first gate on CD45+cells was set (region R1). Next, to eliminate doublets, a gate on single cells in Forward scatter-A (A=area) versus Forward scatter-H (H=height) was set (region R2). These cells were further distinguished from debris via Forward scatter-A and Side scatter-A (region R3). Afterwards, a gate on viable cells (7-AADcells) was set (region R4). B) Cells from region R4 were further separated into 3 subsets: side scatterhigh(SSChigh) cells, which correspond to low density PMN-MDSCs (region R5), CD14+cells (region R6) and SSClowCD14cells (region R7). Low density PMN-MDSCs contained in region R5 were further separated into 4 subsets based on the expression of CD16 and CD11b (gates R8 to R11). C) Cells stained with MDSC Control Cocktail from R6 were displayed with CD14 versus REA Control-FITC, and a region enclosing >99.5% of cells was set (region R12). This region was transferred to the cells labeled with MDSC Staining Cocktail, depicting M-MDSCs as CD14+HLA-DR. D) Cells stained with MDSC Control Cocktail from region R7 were displayed with REA Control-FITC versus REA-Control-PE, and a region above the background staining, containing CD33int.

Related products:

Isolation of tissue resident macrophages/monocytes from healthy human or tumor samples

The CD163 MicroBead Kit, human has been developed for the enrichment of cells based on the expression of the CD163 antigen. CD163 is most abundantly expressed by mature tissue macrophages and peripheral blood monocytes.

 

CD163 MicroBead Kit, human

CD163+cells were isolated from human peripheral blood mononuclear cells (PBMCs) (A) or ovarian carcinoma samples (B) using the CD163 MicroBead Kit, an MS Column, and a MiniMACS™ Separator. Cells were fluorescently stained with CD45-VioBlue®as well as with CD14-FITC and CD163-VioBlue (A) or CD206-FITC and CD163-PE (B) and analyzed by flow cytometry using the MACSQuant®Analyzer. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence.

Related products:

Isolation and analysis of mouse macrophages

We have developed a fast and efficient way to isolate mouse macrophages based on their specific F4/80 markers by using Anti-F4/80 MicroBeads UltraPure, mouse.

Before separation
After separation

Isolation of F4/80+ macrophages.  F4/80+ cells were isolated from spleen single-cell suspension using Anti-F4/80 MicroBeads UltraPure, two MS Columns, and an OctoMACS™ Separator. The cells were fluorescently stained with CD45-VioBlue®, CD11b-APC, and Anti-F4/80-FITC and analyzed by flow cytometry using the MACSQuant® Analyzer. Cell debris and dead cells were excluded from the analysis based on scatter signals and 7-AAD fluorescence.

Isolation and analysis of mouse myeloid cells and MDSCs

We offer various reagents and kits for the isolation of mouse myeloid cells from tissues and tumors. Download the poster and find a comprehensive overview of all myeloid cell markers and products for convenient isolation and analysis.

Working with MDSCs? The Myeloid-Derived Suppressor Cell Isolation Kit, mouse has been developed for the isolation of CD11b+Gr-1+ myeloid cells from mouse lymphoid tissue. 

Download PDF

Poster
Mouse myeloid cells from spleen and lymph nodes

Find out more about products for mouse myeloid cell research in tissues and tumors in this poster.

Differentiation of monocyte-derived macrophages

Macrophages can be generated in vitro from human monocytes using Human M-CSF, premium grade  or Human GM-CSF, premium grade . 
 

MACS Handbook:

Cell culture

Related products:

Related information

Seems like you are coming from USA!
Do you want to visit our website in your country?