Ki-67 Antibody, anti-human/mouse, REAfinity™
Synonyms: MKI67, KIA, MIB-, MIB-1, PPP1R105, Ki67
RECOMBINANT EXTENDED VALIDATION
Bioz Star95/100 Bioz rating
119 Citations26 Images
Clone:
REA183 | B56
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
ICFC, MICS, 3D-IF, IF, IHC, MC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for Ki-67 Antibody, anti-human/mouse, REAfinity™

Intracellular flow cytometry applications
APC
FITC
PE
PE-Vio 615
PE-Vio 770
PerCP-Vio 700
Vio B515
Vio R667
Vio R720
VioGreen
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-120-556, 130-120-416
Description:
Jurkat cells were fixed, permeabilized, stained with Anti-Ki-67 antibodies, and analyzed by flow cytometry using the MACSQuant® Analyzer. The specificity of the conjugated antibodies was confirmed by blocking the binding to the ligand, using pure unconjugated antibodies (left peak). Cell debris and dead cells were excluded from the analysis based on scatter signals.

Application image
MICS (MACSima Imaging Cyclic Staining) applications
APC
FITC
PE
Fixation:
frozen – PFA
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-120-416, 130-120-556
Testing grade:
Fixation:
frozen – PFA
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-120-416, 130-120-556
Testing grade:
Fixation:
frozen – Acetone
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-120-416, 130-120-556
Testing grade:
Fixation:
frozen – Acetone
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-120-416, 130-120-556
Testing grade:
Fixation:
FFPE
Species tested:
human
Tissue used:
tonsil
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-120-416, 130-120-556
Testing grade:
Description:
Immunofluorescence analysis of a formalin-fixed, paraffin-embedded (FFPE) tonsil section. Before staining, antigens were retrieved using heat-induced epitope retrieval (HIER) at pH 9. The section was stained using Ki-67 APC (green) for 10 minutes at room temperature. Nuclei were visualized with Hoechst™ (blue). Scale bar: 30 µm.

Application image
3D-Immunofluorescence applications
Vio 780
Vio B515
Vio G570
Vio R667
Tissue clearing:
MACS® Clearing Kit
Fixation:
PFA
Species tested:
human
Tissue used:
cerebral organoid
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
Vio 780
Used products:
130-135-527
Description:
3D-immunofluorescence analysis of a human cerebral organoid fixed with 4% PFA and subjected to whole-mount immunostaining with Ki-67 Antibody, anti human/mouse, Vio® 780 (magenta). The sample was processed and optically cleared using the MACS® Clearing Kit and imaged with an UltraMicroscope Blaze light sheet instrument. Sample detail image (A), overview image (B). Scale bars: 100 µm (A), 300 µm (B).

A

Application imageView details view details

B

Application imageView details view details
Mass cytometry applications
pure
Conjugate:
pure
Used products:
130-108-060
Extended validation for Ki-67 Antibody, anti-human/mouse, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA183
Ki-67
high
B56
high
20Raj1
high
SolA15
partial
7B11
partial

Cells were incubated with an excess of purified unconjugated Ki-67 (REA183) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for Ki-67. Human peripheral blood mononuclear cells (PBMCs) stimulated with CD3/CD28 antibodies (T Cell TransAct™) for 3 days were stained with a suitable counterstaining followed by a fixation and permeabilization step using the FoxP3 Staining Buffer Set. Cells were then stained with Ki-67 antibodies. As a control, Ki-67 antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. CD4+ cells were pregated for the analysis. Cell debris and cell doublets were excluded from the analysis based on scatter signals. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Specifications for Ki-67 Antibody, anti-human/mouse, REAfinity™
Overview

Clone REA183 recognizes the Ki-67 antigen, a nuclear and nucleolar protein, which is strictly associated with cell proliferation. Two Ki-67 isoforms with molecular weight, 395 and 345 kDa are known. Both isoforms contain 16 “Ki-67 repeat“ sequences, each of which includes a conserved 66 bp “Ki-67 motif“. Expression of Ki-67 protein is present during all active phases of the cell cycle (G(1), S, G(2), and mitosis), but is absent from resting cells (G(0)). Due to strict association of Ki-67 with proliferating cells, Ki-67 is often used as an indicator of the “growth fraction“ of a given cell population. The N-terminal portion of Ki-67 contains a forkhead associated (FHA)1 domain, which is involved in interaction with proteins such as Hklp2 and NIFK.

Additional information: Clone REA183 displays negligible binding to Fc receptors.

Alternative names

MKI67, KIA, MIB-, MIB-1, PPP1R105, Ki67

Detailed product information

Technical specifications

Clone
REA183
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody (I), human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
human, mouse
Antigen
Ki-67
Molecular mass of antigen [kDa]
359
Entrez Gene ID
RRID
AB_2905307, AB_2784398, AB_2905306, AB_2784395, AB_2784396, AB_2752089, AB_2752141, AB_2784394, AB_2801771, AB_2652564, AB_2905304, AB_2905305, AB_2784397, AB_2801762, AB_2784393, AB_2784391, AB_2733585, AB_2784390, AB_2733584, AB_2784392, AB_2784389

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for Ki-67 Antibody, anti-human/mouse, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

You have previously chosen International as your location.
What do you want to do?