Myosin Heavy Chain Antibody, anti-human/mouse/rat, REAfinity™
Synonyms: MYH6, MYH7, MHC, MYHC
RECOMBINANT EXTENDED VALIDATION
Bioz Star92/100 Bioz rating
3 Citations1 Image
Clone:
REA399 | 3-48
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
ICFC, MICS, 3D-IF, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:

Related products for Myosin Heavy Chain Antibody, anti-human/mouse/rat, REAfinity™

Intracellular flow cytometry applications
APC
VioBlue
pure
Recommended dilution:
1:50
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-122-924, 130-122-968
Description:
Heart tissue from P2 Wistar rats was dissociated using the Neonatal Heart Dissociation Kit and the gentleMACS™ Dissociator. Neonatal cardiomyocytes were then fixed, permeabilized, and stained with Anti-Myosin Heavy Chain antibodies or with the corresponding REA Control (I) antibodies (left image). Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris were excluded from the analysis based on scatter signals.

Application imageView details view details

Application imageView details view details
MICS (MACSima Imaging Cyclic Staining) applications
APC
Fixation:
FFPE
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-122-924, 130-122-968
Testing grade:
Fixation:
FFPE
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-122-924, 130-122-968
Testing grade:
Fixation:
frozen – Acetone
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-122-924, 130-122-968
Testing grade:
Fixation:
frozen – PFA
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-122-924, 130-122-968
Testing grade:
Fixation:
frozen – PFA
Species tested:
mouse
Tissue used:
heart
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-122-924, 130-122-968
Testing grade:
Description:
Immunofluorescence analysis of a heart-ventricle cryosection fixed with 4% PFA. The section was stained using Anti-MyosinHC APC (green) for 10 min at room temperature. Sample detail image (A), overview image (B). Nuclei were visualized with Hoechst™ (blue). Scale bar: 30 µm.

Application imageView details view details

Application imageView details view details
3D-Immunofluorescence applications
Vio 780
Vio G570
Vio R667
Tissue clearing:
MACS® Deep Clearing Kit
Fixation:
PFA
Species tested:
human
Tissue used:
heart
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Conjugate:
Vio 780
Used products:
130-136-617
Description:
3D-immunofluorescence analysis of a human cardiac body fixed with 4% PFA and subjected to whole-mount immunostaining with Myosin Heavy Chain Antibody, anti-human/mouse/rat, Vio® 780 (magenta). The sample was processed and optically cleared using the MACS® Deep Clearing Kit and imaged with an UltraMicroscope Blaze light sheet instrument. Sample detail image (A), overview image (B). Scale bars: 50 µm (A), 100 µm (B).

A

Application imageView details view details

B

Application imageView details view details
Extended validation for Myosin Heavy Chain Antibody, anti-human/mouse/rat, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA399
MF20
low
H11
low
3-48 GSC7
low

Cells were incubated with an excess of purified unconjugated Myosin Heavy Chain (REA399) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Specifications for Myosin Heavy Chain Antibody, anti-human/mouse/rat, REAfinity™
Overview

Clone REA399 recognizes the human, mouse, and rat cardiac isoform of the myosin heavy chain (MHC) antigen. Myosin forms cross-bridges with actin in cardiac, smooth, and skeletal muscle, and cyclic cross-bridge activity is the basis for muscular contraction. It is a hexamer composed of two heavy chains, each of which contains an actin-binding site and an ATP hydrolysis site, and four light chains. Isoforms of each myosin subunit are expressed in cardiac, skeletal, and smooth muscle, and many are associated with distinct contractile properties in the muscles or single muscle fibers in which they are expressed. In cardiac muscle, two MHC isoforms, termed α-MHC and β-MHC, are present. α-MHC is associated with higher actomyosin ATPase activity compared with β-MHC. The relative amounts of the two isoforms may vary, with the ratio being a function of the hormonal status, the developmental stage, the animal, or the particular region of the heart.

Additional information: Clone REA399 displays negligible binding to Fc receptors.

Alternative names

MYH6, MYH7, MHC, MYHC

Detailed product information

Technical specifications

Clone
REA399
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody (I), human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
human, mouse, rat, other
Cross-reactivity
rabbit, cow, dog, pig
Antigen
Myosin Heavy Chain
Molecular mass of antigen [kDa]
223, average of subunits
Distribution of antigen
cardiac muscle, skeletal muscle, smooth muscle
Entrez Gene ID
RRID
AB_2889714, AB_2928768, AB_2652981, AB_2889715, AB_2652980, AB_2652979

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for Myosin Heavy Chain Antibody, anti-human/mouse/rat, REAfinity™
Documents and Protocols
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

You have previously chosen International as your location.
What do you want to do?