CD11c Antibody, anti-mouse, REAfinity™
Synonyms: p150, integrin αX, ITGAX, CR4
RECOMBINANT EXTENDED VALIDATION
Bioz Star95/100 Bioz rating
120 Citations54 Images
Clone:
REA754 | N418
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
FC, MICS, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for CD11c Antibody, anti-mouse, REAfinity™

Flow cytometry applications
APC
APC-Vio 770
Biotin
FITC
PE
PE-Vio 770
PerCP-Vio 700
VioBlue
Recommended dilution:
1:50
Remark:
Cells should be stained prior to fixation, if formaldehyde is used as a fixative.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-110-702, 130-110-839
Description:
Splenocytes from C57BL/6 mice were stained with CD11c antibodies or with the corresponding REA Control antibodies (left image) as well as with Anti-MHC Class II antibodies. Flow cytometry was performed using the MACSQuant® Analyzer. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application imageView details view details

Application imageView details view details
MICS (MACSima Imaging Cyclic Staining) applications
APC
FITC
PE
Fixation:
frozen – PFA
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-110-702, 130-110-839
Testing grade:
Fixation:
frozen – Acetone
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-110-702, 130-110-839
Testing grade:
Extended validation for CD11c Antibody, anti-mouse, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA754
N418
high
HL3
high

Cells were incubated with an excess of purified unconjugated CD11c (REA754) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD11c. Splenocytes from C57BL/6 mice were stained with CD11c antibodies and plotted against the side scatter. As a control, CD11c antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD11c (REA754). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for CD11c Antibody, anti-mouse, REAfinity™
Overview

Clone REA754 recognizes the mouse CD11c antigen, also known as integrin αX or Itgax. CD11c is present in dendritic cells in lymphoid organs and blood, in Langerhans cells in the epidermis, in dendritic cell progenitors in the bone marrow, and in in vitro–generated bone marrow–derived dendritic cells. In spleen and lymph node, CD11c is found at high levels on conventional CD11c+CD45R–mPDCA-1– dendritic cells, and at moderate levels on CD11c+CD45R+mPDCA-1+ plasmacytoid dendritic cells. CD11c is reported to be weakly expressed on NK cells, B cells, and T cell subsets. About 1–3% of splenocytes, 2% of bone marrow cells, as well as <1% of lymph node cells and thymocytes express CD11c. CD11c is a receptor for fibrinogen. It mediates cell-cell interaction during inflammatory responses and is involved in monocyte adhesion and chemotaxis.

Additional information: Clone REA754 displays negligible binding to Fc receptors.

Alternative names

p150, integrin αX, ITGAX, CR4

Detailed product information

Technical specifications

Clone
REA754
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody, human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
mouse
Antigen
CD11c
Molecular mass of antigen [kDa]
127
Distribution of antigen
T cells, NK cells, B cells, dendritic cells, granulocytes, macrophages, monocytes, lymphocytes
Entrez Gene ID
RRID
AB_2654713, AB_2654717, AB_2654711, AB_2654719, AB_2654709, AB_2654708, AB_2654715, AB_2654714, AB_2654718, AB_2654712, AB_2654716, AB_2654710, AB_2654705, AB_2654706, AB_2654707

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for CD11c Antibody, anti-mouse, REAfinity™
Documents and Protocols
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

You have previously chosen International as your location.
What do you want to do?