7-AAD Staining Solution is a ready-to-use reagent suitable for the evaluation of cell viability in mono- or multiparametric analyses of human peripheral blood using flow cytometry.
7-AAD (7-amino-actinomycin D) is a fluorescent dye that intercalates into double-stranded DNA (GC rich regions). It is excluded from viable cells, but can penetrate cell membranes of dead or dying cells. Therefore, it can be used instead of propidium iodide (PI) for the evaluation of cell death and apoptosis.
The fluorescence emission maximum for 7-AAD is at 647 nm. When excited at 488 nm, 7-AAD is de
7-AAD Staining Solution is a ready-to-use reagent suitable for the evaluation of cell viability in mono- or multiparametric analyses of human peripheral blood using flow cytometry.
7-AAD (7-amino-actinomycin D) is a fluorescent dye that intercalates into double-stranded DNA (GC rich regions). It is excluded from viable cells, but can penetrate cell membranes of dead or dying cells. Therefore, it can be used instead of propidium iodide (PI) for the evaluation of cell death and apoptosis.
The fluorescence emission maximum for 7-AAD is at 647 nm. When excited at 488 nm, 7-AAD is detected in the red fluorescence channel commonly used for R-phycoerythrin (PE)-Cy®5 tandem dye detection, with minimal spectral overlap into the yellow fluorescence channel commonly used for PE detection.
7-AAD (7-amino-actinomycin D) is a fluorescent dye that intercalates into double-stranded DNA (GC rich regions). It is excluded from viable cells, but can penetrate cell membranes of dead or dying cells. Therefore, it can be used instead of propidium iodide (PI) for the evaluation of cell death and apoptosis.
The fluorescence emission maximum for 7-AAD is at 647 nm. When excited at 488 nm, 7-AAD is detected in the red fluorescence channel commonly used for R-phycoerythrin (PE)-Cy®5 tandem dye detection, with minimal spectral overlap into the yellow fluorescence channel commonly used for PE detection.
Aged human EDTA-treated whole blood samples (3 days old) were stained with 7-AAD Staining Solution using a lyse-wash procedure and analyzed by flow cytometry using the MACSQuant® Analyzer. For analysis, white blood cells were gated based on forward and side scatter properties after exclusion of doublets, cell debris, and red blood cells based. Non-viable or degenerating cells were identified by 7-AAD fluorescence.
To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.
Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.
You have previously chosen International as your location.
What do you want to do?