7-AAD Staining Solution

7-AAD Staining Solution is a ready-to-use reagent for identification and exclusion of interfering non-viable/degenerating cells and therefore suitable as an aid to diagnosis for the evaluation of cell viability in mono- or multiparametric analyses of human leukocytes using flow cytometry.

7-AAD (7-amino-actinomycin D) is a fluorescent dye that intercalates into double-stranded DNA (GC rich regions). It is excluded from viable cells, but can penetrate cell membranes of non-viable or degenerating cells.

The fluorescence emission maximum for 7-AAD is at 647 nm. When excited at 488

... read more
Specifications for 7-AAD Staining Solution
Overview

7-AAD Staining Solution is a ready-to-use reagent for identification and exclusion of interfering non-viable/degenerating cells and therefore suitable as an aid to diagnosis for the evaluation of cell viability in mono- or multiparametric analyses of human leukocytes using flow cytometry.

7-AAD (7-amino-actinomycin D) is a fluorescent dye that intercalates into double-stranded DNA (GC rich regions). It is excluded from viable cells, but can penetrate cell membranes of non-viable or degenerating cells.

The fluorescence emission maximum for 7-AAD is at 647 nm. When excited at 488 nm, 7-AAD is detected in the red fluorescence channel commonly used for R-phycoerythrin (PE)-Cy®5 tandem dye detection, with minimal spectral overlap into the yellow fluorescence channel commonly used for PE detection.

Detailed product information
Background information

7-AAD (7-amino-actinomycin D) is a fluorescent dye that intercalates into double-stranded DNA (GC rich regions). It is excluded from viable cells, but can penetrate cell membranes of non-viable or degenerating cells. The fluorescence emission maximum for 7-AAD is at 647 nm. When excited at 488 nm, 7-AAD is detected in the red fluorescence channel commonly used for R-phycoerythrin (PE)-Cy®5 tandem dye detection, with minimal spectral overlap into the yellow fluorescence channel commonly used for PE detection.

Product data and images for 7-AAD Staining Solution
Figure 1

Aged human EDTA-treated whole blood samples (3 days old) were stained with 7-AAD Staining Solution using a lyse-wash procedure and analyzed by flow cytometry using the MACSQuant® Analyzer. For analysis, white blood cells were gated based on forward and side scatter properties after exclusion of doublets, cell debris, and red blood cells based. Non-viable or degenerating cells were identified by 7-AAD fluorescence.

Resources for 7-AAD Staining Solution
Certificates

Please follow this link to download the Certificate of Conformity (CoC) by lot number.