The StraightFrom® Whole Blood REAlease® CD3 MicroBead Kit was developed for rapid positive selection of CD3+ cells directly from whole blood. No sample preparation is required, including density gradient centrifugation or erythrocyte lysis.
The purified target cells are bead-free, practical for consecutive magnetic isolations, and can be label-free so that epitopes are available for any downstream application.
The StraightFrom® Whole Blood REAlease® CD3 MicroBead Kit was developed for rapid positive selection of CD3+ cells directly from whole blood. No sample preparation is required, including density gradient centrifugation or erythrocyte lysis.
The purified target cells are bead-free, practical for consecutive magnetic isolations, and can be label-free so that epitopes are available for any downstream application.
CD3+ cells are labelled with StraightFrom Whole Blood REAlease CD3-Biotin (REAlease Biotin Complex). Subsequently, StraightFrom Whole Blood REAlease Anti-Biotin MicroBeads (CD3, human) bind to REAlease Biotin Complex. Then, the cell suspension is loaded onto a MACS Column, which is placed in the magnetic field of a MidiMACS or QuadroMACS separator. Using the REAlease Bead Release Reagent, which removes the MicroBeads from the cell, target cells are eluted within the magnetic field. Finally, during the subsequent incubation with the REAlease Release Reagent, the REAlease Biotin Complex monomerizes and dissociates from the cell surface leaving the target cells free of all labels.
StraightFrom Whole Blood REAlease CD3 MicroBead Kit allows the fast isolation of CD3+ cells directly from blood thus minimizing hands-on time and maximizing yields of target cells. The purified CD3+ cells are well-suited for further flow cytometric, functional, or molecular analysis. The isolated CD3+ cell subset is label-free.
Whole Blood columns, Multi-24 Whole Blood Column Block
CD3+ cells were isolated from whole blood using the StraightFrom Whole Blood REAlease CD3 MicroBead Kit, human and Whole Blood Columns. Cells were fluorescently stained with the REAfinity Antibody CD3-FITC and analyzed by flow cytometry using the MACSQuant Analyzer X. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence.
Label-free cells - release of REAlease Biotin Complex: The efficient removal of all labels was shown by using Biotin Antibody-APC to analyze the cells by flow cytometry for the presence of REAlease Biotin Complex. Directly after isolation, the cells showed staining of biotin (“MicroBead-free CD3+ cells”), whereas the label-free CD3+ cells after the REAlease Biotin Complex release were negative for biotin similar to the non-labeled cells before separation.