CD8 Antibody, anti-human
Synonyms: Ly-2, Leu-2, CD8a, MAL, p32, Cd8b1, LY3, Lyt3, P37
EXTENDED VALIDATION
Bioz Star95/100 Bioz rating
305 Citations50 Images
Clone:
BW135/80
Type of antibody:
Primary antibodies
Isotype:
mouse IgG2aκ
Applications:
FC, MICS, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for CD8 Antibody, anti-human

Flow cytometry applications
APC
APC-Vio 770
Biotin
FITC
PE
PE-Vio 770
PerCP
PerCP-Vio 700
Vio Bright FITC
VioBlue
VioGreen
Recommended dilution:
1:50
Remark:
Cells should be stained prior to fixation, if formaldehyde is used as a fixative.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-113-716, 130-113-154
Description:
Human peripheral blood mononuclear cells (PBMCs) were stained with CD8 antibodies or with the corresponding isotype control antibodies (left images) and analyzed by flow cytometry using the MACSQuant® Analyzer. The Tandem Signal Enhancer has been used to increase binding specificity of tandem-dye–conjugated antibodies. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application imageView details view details

Application imageView details view details
MICS (MACSima Imaging Cyclic Staining) applications
APC
FITC
PE
Fixation:
frozen – PFA
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC, ICC
Conjugate:
APC
Used products:
130-113-716, 130-113-154
Testing grade:
Fixation:
frozen – Acetone
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC, ICC
Conjugate:
APC
Used products:
130-113-716, 130-113-154
Testing grade:
Extended validation for CD8 Antibody, anti-human
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with BW135/80
37006
partial
OKT8
partial
REA734
partial
HIT8a
partial
REAL100
partial
RPA-T8
high
SK1
partial

Cells were incubated with an excess of purified unconjugated CD8 (BW135/80) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD8. Human peripheral blood mononuclear cells (PBMCs) were stained with CD8 antibodies and with a suitable counterstaining. As a control, CD8 antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD8 (BW135/80). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for CD8 Antibody, anti-human
Overview

The monoclonal antibody BW135/80 recognizes the human CD8 antigen which is strongly expressed on human cytotoxic T cells and thymocytes, and is also expressed on a subset of NK cells. The CD8 antigen is a disulfide-linked dimer that exists either as a CD8α homodimer or as a CD8α/β heterodimer. CD8 acts as a co-receptor for the T cell receptor and binds to the MHC class I molecule. The CD8 antibody recognizes the α-subunit of the antigen.

Alternative names

Ly-2, Leu-2, CD8a, MAL, p32, Cd8b1, LY3, Lyt3, P37

Detailed product information

Technical specifications

Clone
BW135/80
Clonality
monoclonal
Isotype
mouse IgG2aκ
Isotype control
Isotype Control Antibody, mouse IgG2a
Host
mouse
Type of antibody
Primary antibodies
Species reactivity
human, non-human primate
Cross-reactivity
rhesus monkey (Macaca mulatta), cynomolgus monkey (Macaca fascicularis)
Antigen
CD8
Molecular mass of antigen [kDa]
45, sum of molecular weights of subunits
Distribution of antigen
dendritic cells, NK cells, red blood cells, T cells, thymocytes
Entrez Gene ID
RRID
AB_2725984, AB_2725987, AB_2726262, AB_2726263, AB_2726261, AB_2725992, AB_2726258, AB_2725985, AB_2726267, AB_2726260, AB_2726257, AB_2725982, AB_2726265, AB_2725990, AB_2726266, AB_2725988, AB_2725989, AB_2726264, AB_2725991, AB_2726259, AB_2725983, AB_2725986
Resources for CD8 Antibody, anti-human
Documents and Protocols
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

You have previously chosen International as your location.
What do you want to do?