- Always use freshly prepared reagents. Failure to do so may lead to suboptimal results.
Immunostaining and clearing of mouse brain for 3D imaging analysis using the MACS® Deep Clearing Kit
This application protocol describes step-by-step the immunostaining and clearing of mouse brain tissue using the MACS Deep Clearing Kit for downstream 3D imaging analysis. The MACS Deep Clearing Kit enables the immunostaining and clearing of up to 20 brain hemispheres or whole brains from mice of any age.
Protocol
Immunostaining and clearing of of mouse brain for 3D imaging analysis using the MACS Deep Clearing Kit
Fixation
1 day
Predehydration (optional)
1 day
Permeabilization
7–14 days
Immunostaining
1 day
Washing
2 days
Dehydration
24 h
Clearing
Imaging
Preparation of PFA buffer
- All steps that include paraformaldehyde (PFA) must be performed under a fume hood.
- The protocol describes the preparation of 500 mL of 4% PFA buffer. For higher or lower volumes scale the amounts of the components accordingly.
- Do not use ready-to-use PFA solutions.
- Add 20 g of PFA powder to 400 mL of PBS and stir the mixture at +60 °C under a fume hood until it is dissolved.
▲ Note: Do not boil.
▲ Note: PFA powder does not dissolve instantly. - Add 0.2–0.4 g of NaOH and continue stirring at +60 °C until the solution clears up. This may take 2–3 hours.
- Adjust the pH to 7.2–7.4 with HCl and NaOH.
- Adjust the volume to 500 mL with PBS.
- Filter the solution using a 0.22 µm filter.
- Store PFA buffer at +4 °C for one week. For long-term storage prepare aliquots and store at –20 °C. Avoid repeated freeze/thaw cycles.
Preparation of Deep Antibody Staining Solution (1×)
- Before preparing the dilution, make sure that the Deep Antibody Staining Solution (8×) does not contain any precipitates. If precipitates occur due to storage of the Deep Antibody Staining Solution (8×) at low temperature, mix well before preparation of Deep Antibody Staining Solution (1×).
- Deep Antibody Staining Solution (8×) needs to be diluted 1:8 with PBS before use. Prepare Deep Antibody Staining Solution (1×) by diluting 1 mL of Deep Antibody Staining Solution (8×) with 7 mL of PBS. Adjust the volume of Deep Antibody Staining Solution (1×) to the amount of tissue to be cleared.
- Always use freshly prepared Deep Antibody Staining Solution (1×).
Preparation of ethanol/Tween® 20 dilutions for dehydration
- The following solutions are needed:
- Ethanol 30%/Tween® 20
- Ethanol 50%/Tween® 20
- Ethanol 70%/Tween® 20
- Ethanol 90%/Tween® 20
- Absolute (≥99.8%) ethanol/Tween® 20
- Prepare within one or two days before use to ensure the absence of residual water.
- Prepare ethanol dilutions of 30%, 50%, 70%, and 90% in water. Use absolute ethanol (≥99.8%) and sterile distilled water to prepare the dilutions.
- Prepare absolute ethanol (≥99.8%) using activated molecular sieves (3Å; if the ethanol bottle is freshly opened, steps 1–7 are optional).
- Cover the bottom of a heat-resistant glass petri dish with molecular sieves.
- Heat molecular sieves in microwave at 750 W for 2 minutes.
- Mix the sieves before heating again at 750 W for 2 minutes.
- Repeat heating until no liquid vaporizes anymore and sieves are completely dry.
- Let sieves cool down.
- Transfer sieves into a bottle and add absolute ethanol.
- Incubate the sieves for 1–2 days to absorb residual water.
- Filter the needed volume of absolute ethanol from the previous step using a 0.22 µm filter and use sterile distilled water to make the respective (30%, 50%, 70%, 90%) dilutions.
- Add Tween® 20 to each dilution to a final concentration of 2% (v/v).
Preparation of Deep Clearing Solution
- Deep Clearing Solution is ready-to-use, but may freeze when stored at +2 to +8 °C. Therefore, it is recommended to prepare aliquots and store at +2 to +8 °C. Bring aliquots to room temperature (+20 to +25 °C) before proceeding to clearing of samples.
▲ Note: Use polypropylene tubes for preparation of aliquots. Other plastics might not be compatible with Deep Clearing Solution.
- For details on the reagents of the MACS Deep Clearing Kit refer to the respective data sheet.
- Use tweezers to handle the samples.
2.1 Fixation
- For subsequent clearing, it is highly recommended to perfuse mice transcardially with PBS/EDTA buffer, followed by 4% PFA buffer.
- Extract sample after perfusion and collect it in a tube containing PBS/EDTA buffer at +2 to +8 °C.
- Transfer sample into a new tube containing 4% PFA buffer at +2 to +8 °C.
▲ Note: It is possible to fix more than one mouse brain per tube. Make sure brains are fully immersed in PFA buffer. - Incubate for 2 hours at +2 to +8 °C.
▲ Note: In order to avoid autofluorescence, do not extend the incubation time. - Wash sample 3× in PBS.
▲ Note: If not immediately processed for clearing, samples can be stored in PBS/azide buffer at +2 to +8 °C for several weeks. - Use either whole brain or cut the brain into two hemispheres using a scalpel.
2.2 Predehydration (optional)
Predehydration can improve results for intracellular markers e.g., MBP.
▲ Note: Additional validation is required to evaluate epitope stability for other specificities, particularly when performing co-stainings.
▲ Note: For preparation of ethanol dilution refer to section 1. Reagent preparation.
- Incubate the sample in 30% Ethanol/Tween® 20 for 24 hours in a 50 mL tube at +28 °C (keep one sample per 50 mL tube). For incubation, use the Eppendorf ThermoMixer® C with Eppendorf SmartBlock™ at a rotational speed of 450 rpm.
▲ Note: Alternatively, a water bath with shaker can also be used at +28 °C. - Discard solution and proceed to section 2.3 Permeabilization.
2.3 Permeabilization
- Add 5 mL of Deep Permeabilization Solution into a 5 mL tube.
- Transfer one brain hemisphere or whole brain into the tube.
- Incubate for at least 24 hours at room temperature (+20 to +25 °C) under slow continuous rotation using the MACSmix™ Tube Rotator.
- After incubation, discard Deep Permeabilization Solution and immediately proceed to section 2.4 Immunostaining.
2.4 Immunostaining
- Perform all incubation steps protected from light.
- Use Deep Antibody Staining Solution (1×) in the following steps (refer to section 1. Reagent preparation).
- The following protocol has been optimized for fluorochrome-conjugated primary antibodies from Miltenyi Biotec. Refer to the respective Miltenyi Biotec data sheet or product page for recommended dilution. When using other antibodies refer to the manufacturer´s recommendations for antibody dilution, incubation temperature and duration of incubation.
Table 1: Time and volume of Deep Antibody Staining Solution (1×) for immunostaining
| Tissue | Duration of staining | Total staining volume |
| Brain hemisphere | 7 days | 1.5 mL |
| Whole brain | 14 days | 2.0 mL |
- Dilute the primary antibody in Deep Antibody Staining Solution (1×) using a 24-well plate. Refer to table 1 for volumes.
- Transfer the sample into the 24-well plate containing the antibody dilution.
▲ Note: (Optional) Unused wells can be filled with water to prevent evaporation. - Seal the plate with PARAFILM® or adhesive foil to prevent evaporation.
- Incubate the sample with gentle shaking using a horizontal shaker. When using Miltenyi Biotec antibodies, incubate the sample at +37 °C as indicated in table 1.
2.5 Washing
- Add 5 mL of Deep Antibody Staining Solution (1×) into a 5 mL tube.
- Transfer the sample into this tube.
- Washing step 1: To remove unbound antibody, incubate sample under slow, continuous rotation for 4 hours at room temperature (+20 to +25 °C) using the MACSmix Tube Rotator.
- Washing step 2: Discard Deep Antibody Staining Solution (1×) and repeat steps 1 to 3.
- Washing step 3: Perform an additional washing step with 5 mL of Deep Antibody Staining Solution (1×). Incubate overnight at room temperature (+20 to +25 °C) under slow, continuous rotation using the MACSmix Tube Rotator.
- If working with fluorochrome-conjugated primary antibodies, discard Deep Antibody Staining Solution (1×) and continue with section 2.7 Dehydration.
2.6 (Optional) Secondary antibody staining
- Refer to the manufacturer's recommendations for antibody dilution.
- For indirect staining, dilute the secondary antibody in the final volume indicated in table 1. Use a new well to prepare the dilution.
- Incubate the sample in secondary antibody dilution with gentle shaking using a horizontal shaker.
- Repeat section 2.5 Washing before proceeding with 2.7 Dehydration.
2.7 Dehydration
- For preparation of ethanol series refer to section 1. Reagent preparation.
- Dehydrate sample with a series of ethanol dilutions in 50 mL (one sample per 50 mL tube) at 28 °C using the Eppendorf ThermoMixer® C with Eppendorf SmartBlock™ 50 mL at a rotational speed of 450 rpm.
▲ Note: Alternatively, a shaking water bath can be used at +28 °C.
▲ Note: Perform all incubation steps protected from light.
▲ Note: Always use a new tube for each dehydration step. Transfer the sample using tweezers.
▲ Note: All 4 hour incubation steps can be extended to overnight incubation.
- Incubation in 30% Ethanol/Tween® 20 for 4 hours
- Incubation in 50% Ethanol/ Tween® 20 for 4 hours
- Incubation in 70% Ethanol/ Tween® 20 overnight
- Incubation in 90% Ethanol/ Tween® 20 for 4 hours
- Incubation in absolute (≥99.8%) ethanol/Tween® 20 for 4 hours
- Incubation in absolute (≥99.8%) ethanol/Tween® 20 overnight
2.8 Clearing
- Perform all incubation steps protected from light.
- Add 5 mL of Deep Clearing Solution of MACS Deep Clearing Kit into a 5 mL amber polypropylene tube.
▲ Note: Always use polypropylene tubes to incubate samples with Deep Clearing Solution of the MACS Deep Clearing Kit. - Transfer one sample into this tube.
▲ Note: Ensure the tube is completely filled with Deep Clearing Solution. - Incubate at room temperature (+20 to +25 °C) under slow continuous rotation for at least 24 hours using the MACSmix Tube Rotator.
- If image acquisition is performed immediately after clearing, transfer cleared samples into the imaging chamber of a light sheet microscope (e.g. UltraMicroscope II or UltraMicroscope Blaze™). Fill imaging chamber with MACS Imaging Solution and proceed with image acquisition.
If image acquisition is not performed immediately after clearing, do not discard Deep Clearing Solution. Cleared samples can be stored in 5 mL polypropylene or glass tube at room temperature and in the dark for several months.
▲ Note: If not using UltraMicroscope Platforms, refer to the respective manual and data sheet for compatibility of instrument and sample holders.
▲ Note: Do not store cleared samples at +2 to +8 °C, otherwise freezing artefacts and tissue damage may occur.