MACS® Columns for magnetic cell isolation

  • Magnetic cell separation of highly pure and viable cells
  • Different column variations to process low to high cell numbers and sample volumes
  • Supports research at every level: from basic and translational research, to clinical applications

Principle of MACS Columns

MACS Columns are specially engineered so minimal labeling is required to achieve efficient and gentle cell separation of labeled and unlabeled cells.

Infographic showing magnetically labeled cells in a columnarrow leftarrow right

MACS Columns with cell-friendly spheres cradle labeled cells while allowing unlabeled cells to flow through freely, enabling precise and gentle cell isolation for downstream applications.

How do the columns work?

The technology is based on specialized columns featuring cell friendly spheres. When a MACS Column is placed in a magnetic field, a magnetic force is evenly amplified throughout the spheres. The space between the spheres are about 20 times the size of a lymphocyte, allowing unlabeled cells to pass through easily and unharmed. The amplified magnetic field gently retains the labeled cells within the column, while unlabeled cells flow freely, remaining uncompressed. Once the column is removed from the magnetic field, the labeled cells are smoothly released and ready for collection for further applications.

Flexible flow rates with MACS Columns

We offer a variety of different columns, designed to fit your experimental set-up, desired isolation strategy, and specific application. Our range of MACS Columns offers varying flow rates, giving you the freedom to design the optimal strategy to precisely isolate the exact cells you desire. Opting for a slower flow rate increases the retention of labeled cells in the column, while a faster flow rate reduces retention.

For manual isolations, you have the flexibility to regulate the flow rate by choosing different columns, whereas for automated isolations, the flow rate is managed by optimizing the fluidic speed. We offer solutions tailored for every requirement and application.

Infographic showing how different flow rates affect purity and recovery during cell separationarrow leftarrow right
MACS Columns offer flexible flow rates, enabling you to customize the cell isolation process and adjust the interplay between purity and recovery.

Comprehensive overview of our MACS Columns

Whether you want to capture a rare cell population or increase the purity of your target cells, our column technology caters for all your cell isolation needs and applications. Our columns are categorized into four groups, depending on the isolation strategy and starting material. Compare our columns in the table, or dive into the technical details in the section below.

 ColumnIsolation strategyCapacityCompatibility with StraightFrom® Technology*Manual separation(Semi-) Automated separation
The AllroundersLS Column- Positive isolation
- Depletion of magnetically labeled cells
Labeled cells: up to 1×108
Total cells: up to 2×109 (manually), up to 1×109 with MultiMACS Cell24 Separator Plus
✅✅✅
MS Column- Positive isolation
- Depletion of magnetically labeled cells
Labeled cells: up to 1×107
Total cells: up to 2×108
❌✅❌
autoMACS Columns
- Positive isolation
- Depletion of magnetic labeled cells
- Positive isolation directly from human blood products
Labeled cells: up to 2×108
Total cells: up to 4×109
✅❌✅
The Super untouched cellsLD Column- Stringent depletion of even weakly labeled cellsLabeled cells: up to 1×108
Total cells: up to 5×108
❌✅✅
The Heavy-liftersXLS Column- Positive isolation
- Depletion of magnetically labeled cells
Labeled cells: up to 5×108
Total cells: up to 1×1010
✅✅❌
Multi-24 Column Block- Parallel positive or negative isolation of large sample numbers or volumesLabeled cells: up to 1×108 (per single column)
Total cells: up to 1×109 (per single column)
✅❌✅
XS Column- Positive selection of large cell numbersLabeled cells: up to 1×109
Total cells: up to 2×1010
❌✅❌
D Column
- Depletion of large cell numbersLabeled cells: up to 1×109
Total cells: up to 1×1011
❌✅❌
Large Cell Column- Positive isolation of large human or animal cells
Labeled cells: up to 1×107
Total cells: up to 2×108
❌✅❌
For blood productsWhole Blood Column- Positive isolation directly from human whole blood or buffy coatFor volume based capacities, see descriptions below.
✅✅✅
Multi-24 Whole Blood Column Block- Positive selection directly from blood productsFor volume based capacities, see descriptions below.✅❌✅

*See below for exact details on volume capacities.

Detailed column descriptions

1. The ‘Allrounders’ - For positive and negative isolation or depletion

  • The gold standard for the majority of isolations.
  • Choose the column based on cell capacity, or manual vs automated isolation.

LS Column and plunger

LS Column

Cell capacity
Labeled cells: up to 1×108
Total cells: up to 2×109 with manual use, up to 1×109 with MultiMACS™ Cell24 Separator Plus

Volume capacity (StraightFrom Technology)
StraightFrom PBMC Isolation
Whole blood: 10 mL
Buffy coat: 10 mL

Isolation strategy
Positive isolation
Depletion of magnetically labeled cells

Flow rate
Medium

Separator compatibility
Manual: MidiMACS™ Separator, QuadroMACS™ Separator
Semi-automated: MultiMACS Cell24 Separator Plus

MS Column and plunger

MS Column

Cell capacity
Labeled cells: up to 1×107
Total cells: up to 2×108

Isolation strategy
Positive isolation
Depletion of magnetically labeled cells

Flow Rate
Medium

Separator compatibility
Manual: MiniMACS™ Separator, OctoMACS™ Separator

autoMACS® Column

autoMACS® Columns

Cell capacity
Labeled cells: up to 2×108
Total cells: up to 4×109

Volume capacity (StraightFrom Technology)
StraightFrom PBMC Isolation:
Whole blood: 42 mL per stage
Buffy coat: 42 mL per stage

StraightFrom MicroBeads:
Whole blood: 28 mL
Buffy coat: 28 mL

Isolation strategy
Positive isolation
Positive isolation directly from human whole blood
Depletion

Flow rate
Flexible by choice of program or individual tailoring

Separator compatibility
Automated: autoMACS NEO Separator, autoMACS Pro Separator

2. The ‘Super untouched cells’ – For stringent negative isolation or depletion

  • Capable of removing all labeled cells for the highest purity.
  • Suitable for sensitive downstream applications, such as single-cell sequencing.
  • Ideal for depletion of unwanted cells followed by positive isolation from the untouched fraction, for example, the isolation of regulatory T cells.

LD Column and plunger

LD Column

Cell capacity
Labeled cells: up to 1×108
Total cells: up to 5×108

Isolation strategy
Stringent depletion of even weakly labeled cells

Flow rate
Slow

Separator compatibility
Manual: MidiMACS Separator, QuadroMACS Separator
Semi-automated: MultiMACS Cell24 Separator Plus

3. The ‘Heavy-lifters’ – For high volumes of starting material

  • For processing high sample volumes.
  • Capable of processing large cell numbers in a single step.

Multi-24 Column Block

Multi-24 Column Block

Cell capacity
Labeled cells: up to 1×108 (per single column)
Total cells: up to 1×109 (per single column)

Volume capacity (StraightFrom Technology)
StraightFrom PBMC Isolation:
Leukopak®: 50 mL (per column block)
Whole blood: 10ml (per single column)

StraightFrom MicroBeads:
Leukopak®: up to ½ Leukopak per column

Isolation strategy
Parallel positive or negative isolation of large sample numbers or volumes

Flow rate
Medium

Separator compatibility
Semi-automated: MultiMACS Cell24 Separator Plus

XS Column

XS Column

Cell capacity
Labeled cells: up to 1×109
Total cells: up to 2×1010

Isolation strategy
Positive selection of very large cell numbers in one single step

Flow rate
Fast

Separator compatibility
Manual: SuperMACS™ II Separator

D Column with flow resistor

D Column

Cell capacity
Labeled cells: up to 1×109
Total cells: up to 1×1011

Isolation strategy
Depletion of large cell numbers

Flow rate
Based on experiment and flow resistor

Separator compatibility
Manual: SuperMACS II Separator

Large Cell Column and plunger

Large Cell Column

  • Compatible with large cell isolations, such as megakaryocytes.

Cell capacity
Labeled cells: up to 1×107
Total cells: up to 2×108

Isolation strategy
Positive isolation of large human or animal cells

Flow rate
Medium

Separator compatibility
Manual: MiniMACS Separator, OctoMACS Separator

XLS Column and plunger

XLS Column

Cell capacity
Labeled cells: up to 5×108
Total cells: up to 1×1010

Volume capacity (StraightFrom Technology)
StraightFrom PBMC Isolation:
Whole blood: 100 mL
Buffy coat: ½ Buffy coat
Leukopak®: 20 mL

StraightFrom MicroBeads:
Leukopak®: 25 mL

Isolation strategy
Positive isolation
Depletion of magnetically labeled cells

Flow rate
Fast

Separator compatibility
Manual: QuadroMACS XL Separator

4. For blood isolation – Isolating cells directly from blood products

  • Allows processing of low to high blood volumes in single or parallel runs.

Whole Blood Column Kit

Whole Blood Column

Volume capacity (StraightFrom Technology)
StraightFrom MicroBeads:
Whole blood: 15 mL (up to 10 mL with the MultiMACS Cell24 Separator Plus)
Buffy coat: 15 mL (up to 10 mL with the MultiMACS Cell24 Separator Plus)

Isolation strategy
Positive isolation directly from human whole blood or buffy coat

Flow rate
Fast

Separator compatibility
Manual: MidiMACS Separator, QuadroMACS Separator
Semi-automated: MultiMACS Cell24 Separator Plus

Multi-24 Whole Blood Column Block

Multi-24 Whole Blood Column Block

Volume capacity (StraightFrom Technology)
StraightFrom MicroBeads:
Whole blood: 10 mL per single column
Buffy coat: 10 mL per single column

Isolation strategy
Positive selection directly from blood products

Flow rate
Medium

Separator compatibility
Semi-automated: MultiMACS Cell24 Separator Plus

You have previously chosen International as your location.