Immunophenotyping of human CD4+ and CD8+ T cell activation and exhaustion using flow cytometry
MBTP 55 = Miltenyi Biotec-tested panel 55
This application protocol describes the analysis of human CD4+ and CD8+ T cell activation and exhaustion markers after T cell stimulation. To demonstrate this state-of-the-art panel for T cell activation as well as T cell exhaustion of both CD4 T cells and CD8 T cells, PBMCs were stimulated using Miltenyi Biotec’s T Cell TransAct™, human for 72 hours. The state of activation and exhaustion was defined by CD25, CD223, CD279 (PD-1), and CD69 expression.
- Volumes given below are for up to 106 nucleated cells. When working with fewer than 106 cells, use the same volumes as indicated. When working with higher cell numbers, scale up all reagent volumes and total volumes accordingly (e.g. for 2 × 106 nucleated cells, use twice the volume of all indicated reagent volumes and total volumes).
- Cell number was determined.
- Cells were centrifuged at 300 × g for 10 minutes. Supernatant was aspirated completely.
- A staining cocktail with all antibodies was prepared according to the dilutions mentioned in the respective data sheets.
- 100 µL staining cocktail was added to the cells.
- Cells were resuspended and incubated for 10 minutes in the dark at room temperature .
- Cells were washed by addition of 1 mL of PEB buffer and centrifuged at 300 × g for 5 minutes. Supernatant was aspirated completely.
- Cells were resuspended in 100 µL of PEB buffer. 1 µL of 7-AAD Staining Solution was added and incubated for 5 minutes in the dark at room temperature right before flow cytometric analysis using the MACSQuant® Analyzer 10.
Antibody panel for T cell activation and exhaustion
| Specificity | Clone | Purpose | Fluorochrome | Detection filter (nm) (laser) |
| 7-AAD* | - | Viability | - | 655−730 (blue) |
| CD279 (PD-1) | REA1165 | T cell activation and exhaustion | Vio® Bright B515 | 525/50 (blue) |
| CD4 | REA623 | Helper T cells | VioGreen™ | 525/50 (violet) |
| CD8 | REA734 | Cytotoxic T cells | APC-Vio® 770 | 750 LP (red) |
| CD223 | REA351 | T cell activation and exhaustion | APC | 655−730 (red) |
| CD3 | REA613 | T cells | VioBlue® | 450/50 (violet) |
| CD25 | REA570 | T cell activation and exhaustion | PE | 585/40 (blue) |
| CD69 | REA824 | T cell activation and exhaustion | PE-Vio 770 | 750 LP (blue) |
*Alternative CE-IVD/ASR reagent for 7-AAD available (# 170-100-042).
Gating strategy
9 products found
|
For research use only
For research use only
FC
100 tests in 200 µL
(excl. tax)
For research use only
For research use only
FC
100 tests in 200 µL
(excl. tax)
For research use only
For research use only
FC
30 tests in 60 µL
(excl. tax)
For research use only
For research use only
FC
100 tests in 200 µL
(excl. tax)
For research use only
1 mL
(excl. tax)
For research use only
For research use only
FC
100 tests in 200 µL
(excl. tax)
For research use only
For research use only
FC
100 tests in 200 µL
(excl. tax)
For research use only
For research use only
FC
100 tests in 200 µL
(excl. tax)
CE–IVD
for 100 tests
(excl. tax)
You have previously chosen International as your location.
What do you want to do?