StraightFrom® Buffy Coat CD8 MicroBead Kit, human

The StraightFrom® Buffy Coat CD8 MicroBead Kit has been developed for the rapid positive selection of CD8+ cells directly from one buffy coat using the MultiMACS™ Cell24 Separator Plus for semi-automated separation or a MACS® Separator for manual separation. No sample preparation is required, including density gradient centrifugation, erythrocyte lysis, wash steps, or cell count. Whole Blood Columns and Whole Blood Column Elution Buffer are included in the kit to allow direct processing of an entire buffy coat.

qualityAssuranceSatisfaction
guaranteed
more »

Related products for StraightFrom® Buffy Coat CD8 MicroBead Kit, human

Specifications for StraightFrom® Buffy Coat CD8 MicroBead Kit, human
Overview

The StraightFrom® Buffy Coat CD8 MicroBead Kit has been developed for the rapid positive selection of CD8+ cells directly from one buffy coat using the MultiMACS™ Cell24 Separator Plus for semi-automated separation or a MACS® Separator for manual separation. No sample preparation is required, including density gradient centrifugation, erythrocyte lysis, wash steps, or cell count. Whole Blood Columns and Whole Blood Column Elution Buffer are included in the kit to allow direct processing of an entire buffy coat.

Detailed product information
Background information

In blood the CD8 antigen is expressed on human cytotoxic T cells and on a subset of CD16+ NK cells. The CD8 antigen acts as an accessory molecule in the recognition of MHC class I/peptide complexes by the TCR heterodimer on CD8+ cytotoxic T cells.

Detailed separation procedure

One entire buffy coat is labeled with StraightFrom® Buffy Coat CD8 MicroBeads and loaded onto Whole Blood Columns, which are placed in the magnetic field of a MultiMACS™ Cell24 Separator Plus or a MACS® Separator. After removing the column from the magnetic field, the magnetically retained CD8+ cells can be eluted as the positively selected cell fraction.

Downstream applications

The purified CD8+ cells are well-suited for further flow cytometric, functional, or molecular analysis.

Product data and images for StraightFrom® Buffy Coat CD8 MicroBead Kit, human
Figure 1

Separation of a buffy coat sample using the StraightFrom® Buffy Coat CD8 MicroBead Kit and the MultiMACS™ Cell24 Separator Plus with the Single-Column Adapter and Whole Blood Columns. Cells were fluorescently stained with CD3-PE, CD8‑APC, as well as CD45‑VioBlue® and analyzed by flow cytometry using the MACSQuant® Analyzer. Cells were triggered via CD45-VioBlue, cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence.