CD4 Antibody, anti-human
Synonyms: CD4mut, L3T4, Leu-3, T4
EXTENDED VALIDATION
Bioz Star95/100 Bioz rating
260 Citations34 Images
Clone:
VIT4
Type of antibody:
Primary antibodies
Isotype:
mouse IgG2aκ
Applications:
FC, MICS, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for CD4 Antibody, anti-human

Flow cytometry applications
APC
APC-Vio 770
Biotin
FITC
PE
PE-Vio 615
PE-Vio 770
PerCP
PerCP-Vio 700
Vio Bright FITC
Vio Bright R667
VioBlue
VioGreen
Recommended dilution:
1:50
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-113-772, 130-113-210
Description:
Human peripheral blood mononuclear cells (PBMCs) were stained with CD4 antibodies or with the corresponding isotype control antibodies (left images) and analyzed by flow cytometry using the MACSQuant® Analyzer. The Tandem Signal Enhancer has been used to increase binding specificity of tandem-dye–conjugated antibodies. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application imageView details view details

Application imageView details view details
MICS (MACSima Imaging Cyclic Staining) applications
APC
FITC
PE
Fixation:
frozen – PFA
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC, ICC
Conjugate:
APC
Used products:
130-113-772, 130-113-210
Testing grade:
Fixation:
frozen – Acetone
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-113-772, 130-113-210
Testing grade:
Extended validation for CD4 Antibody, anti-human
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with VIT4
RPA-T4
high
REA623
low
M-T466
low
M-T321
low
SK3
low
OKT4
low

Cells were incubated with an excess of purified unconjugated CD4 (VIT4) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD4. Human peripheral blood mononuclear cells (PBMCs) were stained with CD4 antibodies and with a suitable counterstaining. As a control, CD4 antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Monocytes were excluded from the analysis. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD4 (VIT4). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for CD4 Antibody, anti-human
Overview

Clone VIT4 recognizes the human CD4 antigen which is highly expressed on human T helper cells and thymocytes, and at lower levels on monocytes and dendritic cells. It is responsible for the recognition of the MHC class II antigen.

VIT4 can be used for evaluating the transfection efficiency of cells transfected with pMACS 4.1 or pMACS 4-IRES when using the MACSelect™ – 4 Transfected Cell Selection Kit.

Alternative names

CD4mut, L3T4, Leu-3, T4

Detailed product information

Technical specifications

Clone
VIT4
Clonality
monoclonal
Isotype
mouse IgG2aκ
Isotype control
Isotype Control Antibody, mouse IgG2a
Host
mouse
Type of antibody
Primary antibodies
Species reactivity
human
Antigen
CD4
Molecular mass of antigen [kDa]
48
Distribution of antigen
dendritic cells, granulocytes, Langerhans cells, lymphocytes, macrophages, monocytes, T cells, neutrophils, T helper cells, thymocytes
Entrez Gene ID
RRID
AB_2726029, AB_2726702, AB_2726028, AB_2726305, AB_2726030, AB_2726307, AB_2726301, AB_2726297, AB_2726304, AB_2726300, AB_2726022, AB_2751052, AB_2726306, AB_2726031, AB_2726302, AB_2726023, AB_2751058, AB_2726298, AB_2726025, AB_2726026, AB_2726299, AB_2726024, AB_2726303, AB_2726021, AB_2726296, AB_2726027, AB_2726032
Resources for CD4 Antibody, anti-human
Documents and Protocols
App notes/customer reports
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support