CD101 Antibody, anti-mouse, REAfinity™
Synonyms: EWI-101, Gm1016, Gm734, IGSF2
RECOMBINANT EXTENDED VALIDATION
Bioz Star94/100 Bioz rating
13 Citations
Clone:
REA301 | Moushi101
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
FC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:

Related products for CD101 Antibody, anti-mouse, REAfinity™

Flow cytometry applications
APC
Biotin
PE
PE-Vio 770
Recommended dilution:
1:50
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-126-310
Description:
Splenocytes from BALB/c mice were stained with CD101 antibodies as well as with Anti-Ly-6G antibodies and analyzed by flow cytometry using the MACSQuant® Analyzer. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application image
Extended validation for CD101 Antibody, anti-mouse, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA301
Moushi101
partial
307707
high
REAL172
high

Cells were incubated with an excess of purified unconjugated CD101 (REA301) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD101 shown as histograms

Specifications for CD101 Antibody, anti-mouse, REAfinity™
Overview

Clone REA301 recognizes the mouse CD101 antigen, a type I transmembrane glycoprotein also known as immunoglobulin superfamily member 2 (IgSF2) or V7. CD101 is expressed on monocytes, granulocytes, dendritic cells (DCs), and activated T cells. In humans CD101 inhibits the proliferative response of T cells to allogeneic cells or immobilized anti-CD3 antibody, suggesting that engagement of CD101 can antagonize TCR/CD3-mediated lymphocyte activation. Moreover, human peripheral CD8+ T cells that express CD101 and CD103 display suppressive function after activation with intraepithelial cells or placental trophoblasts. In addition to its role on T cells, triggering CD101 on human cutaneous DCs inhibits T cell proliferation via interleukin 10 (IL-10) production, suggesting that the CD101 molecule may be involved in tolerance induction. Studies in mice showed that cell surface expression of CD101 is highly correlated with functional suppressor activity within CD4+CD25+ T regulatory cells both in vitro and in vivo.

Additional information: Clone REA301 displays negligible binding to Fc receptors.

Alternative names

EWI-101, Gm1016, Gm734, IGSF2

Detailed product information

Technical specifications

Clone
REA301
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody, human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
mouse
Antigen
CD101
Molecular mass of antigen [kDa]
112
Distribution of antigen
granulocytes, monocytes, dendritic cells, T cells
Entrez Gene ID
RRID
AB_2904656, AB_2752032, AB_2654348, AB_2654347, AB_2654346, AB_2654345

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for CD101 Antibody, anti-mouse, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

You have previously chosen International as your location.
What do you want to do?