CD73 Antibody, anti-mouse, REAfinity™
Synonyms: NT5E, NT, Nt5, eNT
RECOMBINANT EXTENDED VALIDATION
Bioz Star92/100 Bioz rating
11 Citations3 Images
Clone:
REA778 | TY/11.8
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
FC, MICS, 3D-IF, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:

Related products for CD73 Antibody, anti-mouse, REAfinity™

Flow cytometry applications
APC
APC-Vio 770
Biotin
PE
PE-Vio 770
Vio Bright B515
Recommended dilution:
1:50
Remark:
Cells should be stained prior to fixation, if formaldehyde is used as a fixative.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-111-518, 130-111-332
Description:
Splenocytes from BALB/c mice were stained with CD73 antibodies or with the corresponding REA Control antibodies (left image) as well as with CD3ε antibodies. Flow cytometry was performed using the MACSQuant® Analyzer. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application imageView details view details

Application imageView details view details
MICS (MACSima Imaging Cyclic Staining) applications
APC
PE
Fixation:
frozen – PFA
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-111-332, 130-111-518
Testing grade:
Fixation:
frozen – Acetone
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-111-332, 130-111-518
Testing grade:
3D-Immunofluorescence applications
Vio R667
Tissue clearing:
MACS® Clearing Kit
Fixation:
PFA
Species tested:
mouse
Tissue used:
lymph node
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Conjugate:
Vio R667
Used products:
130-131-557
Description:
3D-immunofluorescence analysis of mouse lymph node fixed with 4% PFA and subjected to whole-mount immunostaining with CD73 Antibody, anti-mouse, Vio® R667 (red). The sample was processed and optically cleared using the MACS® Clearing Kit and imaged with an UltraMicroscope Blaze light sheet instrument. Sample detail image (A), overview image (B), 3D-rendered maximum intensity projection (C) and 3D-rendered video (D). Scale bars: 100 µm (A), 500 µm (B, C).

A

Application imageView details view details

B

Application imageView details view details

C

Application imageView details view details
Extended validation for CD73 Antibody, anti-mouse, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA778
TY/23
low
TY/11.8
high

Cells were incubated with an excess of purified unconjugated CD73 (REA778) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD73. Splenocytes from C57BL/6 mice were stained with CD73 antibodies and with a suitable counterstaining. As a control, CD73 antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD73 (REA778). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD73 (REA778). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for CD73 Antibody, anti-mouse, REAfinity™
Overview

Clone REA778 recognizes the mouse CD73 antigen, also known as ecto-5'-nucleotidase. CD73 is a glycosyl phosphatidylinositol (GPI)-linked membrane-bound glycoprotein and dephosphorylates extracellular nucleoside monophosphatase into nucleosides. Expression of CD73 is found in subsets of myeloid cells, T cells,and thymic epithelial cells. CD73 together with ectozyme CD39 regulates the extracellular ATP and adenosine levels.

Additional information: Clone REA778 displays negligible binding to Fc receptors.

Alternative names

NT5E, NT, Nt5, eNT

Detailed product information

Technical specifications

Clone
REA778
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody, human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
mouse
Antigen
CD73
Molecular mass of antigen [kDa]
58
Distribution of antigen
T cells
Entrez Gene ID
RRID
AB_2659160, AB_2659156, AB_2659161, AB_2659163, AB_2659162, AB_2659159, AB_2659152, AB_2659153, AB_2659158, AB_2659157, AB_2659155, AB_2659154

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for CD73 Antibody, anti-mouse, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

You have previously chosen International as your location.
What do you want to do?