- Clone:
- REA183 | B56
- Type of antibody:
- Primary antibodies, Recombinant antibodies
- Isotype:
- recombinant human IgG1
- Applications:
- ICFC, MICS, 3D-IF, IF, IHC, MC Glossary
- Select a conjugate:
- Select a size:
Related products for Ki-67 Antibody, anti-human/mouse, REAfinity™
A
B
In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.
Cells were incubated with an excess of purified unconjugated Ki-67 (REA183) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.
Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.
Flow cytometric comparison of different clones for Ki-67. Human peripheral blood mononuclear cells (PBMCs) stimulated with CD3/CD28 antibodies (T Cell TransAct™) for 3 days were stained with a suitable counterstaining followed by a fixation and permeabilization step using the FoxP3 Staining Buffer Set. Cells were then stained with Ki-67 antibodies. As a control, Ki-67 antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. CD4+ cells were pregated for the analysis. Cell debris and cell doublets were excluded from the analysis based on scatter signals. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.
Clone REA183 recognizes the Ki-67 antigen, a nuclear and nucleolar protein, which is strictly associated with cell proliferation. Two Ki-67 isoforms with molecular weight, 395 and 345 kDa are known. Both isoforms contain 16 “Ki-67 repeat“ sequences, each of which includes a conserved 66 bp “Ki-67 motif“. Expression of Ki-67 protein is present during all active phases of the cell cycle (G(1), S, G(2), and mitosis), but is absent from resting cells (G(0)). Due to strict association of Ki-67 with proliferating cells, Ki-67 is often used as an indicator of the “growth fraction“ of a given cell population. The N-terminal portion of Ki-67 contains a forkhead associated (FHA)1 domain, which is involved in interaction with proteins such as Hklp2 and NIFK.
Additional information: Clone REA183 displays negligible binding to Fc receptors.
MKI67, KIA, MIB-, MIB-1, PPP1R105, Ki67
Technical specifications
Recombinant antibodies at Miltenyi Biotec
As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.
The Miltenyi way of generating best-in-class antibodies and antibody conjugates
At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.
Infusing our unique expertise
Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.
Maximizing value for your research
By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:
reduce undesirable binding to Fc gamma receptors,
- eliminate destabilizing amino acid motifs,
- increase specific bonding affinity for stronger, more accurate targeting, and
- optimize fluorochrome conjugation for brighter and clearer signals.
In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.
Better science with quality antibodies
Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).
To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.
Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.
You have previously chosen International as your location.
What do you want to do?