Key features of the

CliniMACS® Tubing Sets and Accessories

The single-use CliniMACS Tubing Sets provide a closed and sterile fluid pathway for your cells during clinical-scale cell enrichment or depletion on the CliniMACS Plus Instrument. Learn more about the cell separation workflows and choose the tubing set optimized for your strategy.

For complete regulatory notes click here.

CliniMACS Tubing Set

Seamless cell enrichment

The CliniMACS Tubing Set and the CliniMACS Tubing Set LS are designed for the enrichment of magnetically labeled cells.

How it works: First, the Cell Preparation Bag, containing the labeled target cells, is connected to the tubing set via the bubble trap spike and the Pre-System Filter. The cells then pass through the pre-column, which serves to remove cells with non-specific interactions with the column matrix. Next, the cells are applied to the separation column, where the magnetic field retains labeled cells while unlabeled cells flow through. Once separation is complete, the magnetic field is deactivated and the labeled cells are eluted from the column. The enriched cell fraction is collected in a cell collection bag of your choice connected via the luer connector, while the unlabeled cells are collected in the Negative Fraction Bag.

The CliniMACS Tubing Set is designed to process up to 6.0 × 10⁹ total white blood cells (WBC), whereas the CliniMACS Tubing Set LS has a larger cell separation column and can handle up to 1.2 × 10¹⁰ total WBC.

CliniMACS Depletion Tubing Set
Please note: The Cell Preparation Bag and the Pre-System Filter are not part of the tubing set.

Automated cell depletion

The CliniMACS Depletion Tubing Set is specifically designed for the fast removal of a large number of magnetically labeled cells.

How it works: The Cell Preparation Bag, which contains the magnetically labeled non-target cells, is connected to the tubing set via the spike connector and the Pre-System Filter. The cells are then applied to the separation column. During cell depletion, the labeled non-target cells are retained in the column, while the unlabeled target cells pass through into the Cell Collection Bag. Once separation is complete, the retained labeled non-target cells are eluted and collected in the Non-Target Cell Bag.

The CliniMACS Depletion Tubing Set supports a two–step depletion strategy, combining bulk and sensitive depletion steps to achieve optimal results.

The CliniMACS Tubing Set LS also supports depletion applications through a single step of sensitive depletion.

CliniMACS Plus Tubing Sets at a glance

The CliniMACS Plus Tubing Sets offer flexibility for a wide range of clinical applications, enabling precise selection of cell types for enrichment or depletion based on your needs. Their compatibility with various cell subsets facilitates tailored processing for both clinical research and therapy manufacturing.

Type of tubing setApplicationsCell types and subsets
CliniMACS Tubing SetCell enrichmentCD34+ HSCs, CD4+, CD8+, CD25+, CD56+, CD14+
CliniMACS Tubing Set LSCell enrichment

Cell depletion
CD34+ HSCs

CD19+, CD3+, CD4+, CD4+/CD8+ combination, CD25+, CD3+/CD19+ combination
CliniMACS Depletion Tubing SetCell depletionTCRαβ+ T cells, TCRαβ+ T cells/CD19+ combination, CD45RA+ cells, CD3+, CD3+/CD19+ combination

Accessories for CliniMACS Plus Tubing Sets

A variety of accessories is available to enable modular connections and flexible handling.

AccessoryUsed for
Transfer Set Coupler/CouplerConnects the CliniMACS PBS/EDTA Buffer bag to the Cell Preparation Bag, or two buffer bags during the cell labeling process
Luer/Spike InterconnectorAttaches the Cell Collection Bag to the CliniMACS Tubing Set
Pre-System FilterRetains cell aggregates and debris to support optimal flow

All CliniMACS Tubing Sets and Accessories

5 products found

|

You have previously chosen International as your location.
What do you want to do?