CD42a Antibody, anti-human, REAfinity™
Synonyms: GP9, GPIX
RECOMBINANT EXTENDED VALIDATION
Bioz Star94/100 Bioz rating
10 Citations2 Images
Clone:
REA209 | ALMA.16
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
FC, MICS, IF, IHC, MC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for CD42a Antibody, anti-human, REAfinity™

Flow cytometry applications
APC
APC-Vio 770
Biotin
FITC
PE
PE-Vio 770
PerCP-Vio 700
Vio Bright B515
Vio Bright R720
Recommended dilution:
1:50
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-124-028, 130-123-831
Description:
Human peripheral blood cells, after erythrocyte lysis, were stained with CD42a antibodies and analyzed by flow cytometry using the MACSQuant® Analyzer. The specificity of the conjugated antibodies was confirmed by blocking the binding to the ligand, using pure unconjugated antibodies (left peak). CD61+ cells were pre-gated for the analysis. The Tandem Signal Enhancer has been used to increase binding specificity of tandem-dye–conjugated antibodies. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application image
MICS (MACSima Imaging Cyclic Staining) applications
APC
FITC
PE
Fixation:
frozen – PFA
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC, ICC
Conjugate:
APC
Used products:
130-123-831, 130-124-028
Testing grade:
Mass cytometry applications
pure
Conjugate:
pure
Used products:
130-122-338
Extended validation for CD42a Antibody, anti-human, REAfinity™
Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD42a. Human peripheral blood platelets were stained with CD42a antibodies and with a suitable counterstaining. As a control, CD42a antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD42a shown as histograms

Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD42a (REA209). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for CD42a Antibody, anti-human, REAfinity™
Overview

Clone REA209 recognizes CD42a, a 22 KDa transmembrane glycoprotein, which is also known as glycoprotein IX (GPIX). CD42a is a single-pass type I membrane protein with leucine rich motif containing a series of tandem repeats of a 24-amino acid sequence flanked by conserved disulfide loops, in its ligand binding domains. Expression of CD42a is found on platelets and megakaryocytes. CD42a, together with GPIb receptor complex and platelet glycoprotein V forms a complex which serves as the receptor for von Willebrand factor (VWF). The interaction of the GPIb-IX-V complex to VWF initiates initial platelet adhesion to vascular subendothelium after vascular injury, platelet activation, thrombosis, and hemostasis. Other known ligands for GPIb–IX–V include α-thrombin, clotting factors XI/XIIa, and high-molecular weight kininogen.

Additional information: Clone REA209 displays negligible binding to Fc receptors.

Alternative names

GP9, GPIX

Detailed product information

Technical specifications

Clone
REA209
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody (S), human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
human
Antigen
CD42a
Molecular mass of antigen [kDa]
22
Distribution of antigen
megakaryocytes, platelets
Entrez Gene ID
RRID
AB_2876977, AB_2921962, AB_2921942, AB_2801917, AB_2659741, AB_2857664, AB_2876976, AB_2857642, AB_2659742, AB_2659740, AB_2905007, AB_2659739, AB_2905006

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for CD42a Antibody, anti-human, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

You have previously chosen International as your location.