CD34 Antibody, anti-human, REAfinity™
Synonyms: gp105-120, Mucosialin, My10
RECOMBINANT EXTENDED VALIDATION
Bioz Star94/100 Bioz rating
37 Citations10 Images
Clone:
REA1164 | AC136
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
FC, MICS, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for CD34 Antibody, anti-human, REAfinity™

Flow cytometry applications
APC
APC-Vio 770
Biotin
PE
PE-Vio 615
PE-Vio 670
PE-Vio 770
PerCP-Vio 700
Vio Bright B515
Vio Bright V600
VioBlue
VioGreen
Recommended dilution:
1:50
Remark:
Cells should be stained prior to fixation, if formaldehyde is used as a fixative.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-120-514, 130-120-519
Description:
Human peripheral blood cells (PBMCs) were stained with CD34 antibodies or with the corresponding REA Control (S) antibodies (left images) as well as with CD45 antibodies. CD45+ cells were pre-gated for the analysis. Flow cytometry was performed using the MACSQuant® Analyzer. The Tandem Signal Enhancer has been used to increase binding specificity of tandem-dye–conjugated antibodies. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application imageView details view details

Application imageView details view details
MICS (MACSima Imaging Cyclic Staining) applications
APC
PE
Fixation:
frozen – PFA
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-120-514, 130-120-519
Testing grade:
Fixation:
frozen – Acetone
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-120-514, 130-120-519
Testing grade:
Extended validation for CD34 Antibody, anti-human, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA1164
561
high
581
high
563
high
8G12
high
4H11
high
QBEND/10
low
AC136
high

Cells were incubated with an excess of purified unconjugated CD34 (REA1164) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD34. Human peripheral blood mononuclear cells (PBMCs) were stained with CD34 antibodies and with a suitable counterstaining. As a control, CD34 antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD34 (REA1164). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for CD34 Antibody, anti-human, REAfinity™
Overview

Clone REA1164 recognizes a class III epitope of the CD34 antigen. This epitope is different than the one recognized by the clone used in the CD34 MicroBead Kits.

The CD34 antigen is a single-chain transmembrane glycoprotein, expressed on human hematopoitetic stem and progenitor cells, endothelial progenitor cells, vascular endothelial cells, embryonic fibroblasts, and some cells in fetal and adult nervous tissue. The antigen is absent on fully differentiated hematopoietic cells such as normal peripheral blood lymphocytes, monocytes, granulocytes, erythrocytes, and platelets. CD34 antibodies can be used for studies of hematopoiesis and non-hematopoiectic stem cells, phenotyping of hematopoietic stem cells, and studies on phenotyping of hematologic malignancies, endothelial cells, and endothelial progenitor cells (EPCs).

Additional information: Clone REA1164 displays negligible binding to Fc receptors.

Alternative names

gp105-120, Mucosialin, My10

Detailed product information

Technical specifications

Clone
REA1164
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody (S), human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
human
Antigen
CD34
Molecular mass of antigen [kDa]
37
Distribution of antigen
endothelial cells, stem cells, hematopoietic stem and progenitor cells, fetal neuronal progenitor cells, neural stem cells, fetal neuronal progenitor cells
Entrez Gene ID
RRID
AB_2811346, AB_2811676, AB_2811671, AB_2811669, AB_2811675, AB_2811672, AB_2811674, AB_2811345, AB_2811337, AB_2811343, AB_2811342, AB_2811340, AB_2811668, AB_2811673, AB_2811338, AB_2811344, AB_2811339, AB_2811341, AB_2811670

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for CD34 Antibody, anti-human, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

You have previously chosen International as your location.
What do you want to do?