Histone H3 pS28 Antibody, anti-human/mouse, REAfinity™
Synonyms: H3F3B, H3.3B, H3.3A, H3F3, H3F3A, H3 (pS28), H3.1, H3.2, H3.3
RECOMBINANT
Bioz Star94/100 Bioz rating
5 Citations1 Image
Clone:
REA379 | HTA28
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
ICFC, MICS, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for Histone H3 pS28 Antibody, anti-human/mouse, REAfinity™

Intracellular flow cytometry applications
APC
FITC
PE
Description:
Mouse 1881 pre–B lymphoma cells were treated with demecolcine for 4 hours, fixed, and permeabilized using the Cell Signaling Buffer Set A. Cells were then stained with Anti-Histone H3 pS28 antibodies or with the corresponding REA Control (I) antibodies (left images). After the staining, the cells were treated with 1 mg/mL RNase for 30 minutes and then stained with 4',6-diamidino-2-phenylindole (DAPI) or propidium iodide. Flow cytometry was performed using the MACSQuant® Analyzer. Cell debris were excluded from the analysis based on scatter signals.
Intracellular flow cytometry applications
APC
FITC
PE
PerCP-Vio 700
Recommended dilution:
1:50
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-126-509, 130-126-546
Description:
Mouse 1881 pre–B lymphoma cells were treated with demecolcine for 4 hours, fixed, and permeabilized using the Cell Signaling Buffer Set A. Cells were then stained with Anti-Histone H3 pS28 antibodies or with the corresponding REA Control (I) antibodies (left images). After the staining, the cells were treated with 1 mg/mL RNase for 30 minutes and then stained with 4',6-diamidino-2-phenylindole (DAPI) or propidium iodide. Flow cytometry was performed using the MACSQuant® Analyzer. Cell debris were excluded from the analysis based on scatter signals.

Application imageView details view details

Application imageView details view details
Recommended dilution:
1:11
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-105-701
Description:
Mouse 1881 pre–B lymphoma cells were treated with demecolcine for 4 hours, fixed, and permeabilized using the Cell Signaling Buffer Set A. Cells were then stained with Anti-Histone H3 pS28 antibodies or with the corresponding REA Control (I) antibodies (left images). After the staining, the cells were treated with 1 mg/mL RNase for 30 minutes and then stained with 4',6-diamidino-2-phenylindole (DAPI) or propidium iodide. Flow cytometry was performed using the MACSQuant® Analyzer. Cell debris were excluded from the analysis based on scatter signals.

Application imageView details view details

Application imageView details view details
MICS (MACSima Imaging Cyclic Staining) applications
APC
FITC
PE
Fixation:
frozen – Acetone
Species tested:
mouse
Recommended dilution:
1:11
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-105-701
Testing grade:
Fixation:
frozen – Acetone
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-126-509, 130-126-546
Testing grade:
Fixation:
frozen – Acetone
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-126-509, 130-126-546
Testing grade:
Fixation:
frozen – PFA
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-126-509, 130-126-546
Testing grade:
Fixation:
frozen – PFA
Species tested:
mouse
Recommended dilution:
1:11
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-105-701
Testing grade:
Fixation:
frozen – Acetone
Species tested:
human
Recommended dilution:
1:11
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-105-701
Testing grade:
Specifications for Histone H3 pS28 Antibody, anti-human/mouse, REAfinity™
Overview

Clone REA379 recognizes the human and mouse histone H3 antigen phosphorylated at serine 28 (pS28). Histone H3 is one of the five main histone proteins involved in the structure of chromatin in eukaryotic cells. The N-terminal tail of histone H3 protrudes from the globular nucleosome core and can undergo several different types of post-translational modification that influence cellular processes. These modifications include the covalent attachment of methyl or acetyl groups to lysine and arginine amino acids and the phosphorylation of serine or threonine. Phosphorylation of histone H3 at pS10 and pS28 is very important for chromosome condensation and segregation during mitosis. The phosphorylation of histone H3 at pS10 appears to be involved in the initiation of chromosome condensation but not the maintenance of it. Although phosphorylation of histone H3 at pS10 is related to chromosome assembly, congregation at the metaphase plate, and segregation, phosphorylation of histone H3 at pS28 occurs in chromosomes predominantly during early mitosis and coincides with the initiation of mitotic chromosome condensation in various mammalian cell lines.

Additional information: Clone REA379 displays negligible binding to Fc receptors.

Alternative names

H3F3B, H3.3B, H3.3A, H3F3, H3F3A, H3 (pS28), H3.1, H3.2, H3.3

Detailed product information

Technical specifications

Clone
REA379
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody (I), human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
human, mouse, rat, other
Cross-reactivity
Drosophila, rat, cow
Antigen
Histone H3 pS28
Molecular mass of antigen [kDa]
15
Distribution of antigen
other
Entrez Gene ID
RRID
AB_2889682, AB_2905228, AB_2889684, AB_2889683, AB_2651991, AB_2651995, AB_2651992, AB_2889681

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for Histone H3 pS28 Antibody, anti-human/mouse, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

You have previously chosen International as your location.
What do you want to do?