- Always freshly prepare reagents. Failure to do so may lead to suboptimal results.
Immunostaining and clearing of mouse intestine and lung for 3D imaging analysis
This application protocol describes step-by-step the immunostaining and clearing of mouse intestine or lung tissue using the MACS® Clearing Kit for downstream 3D imaging analysis. The MACS Clearing Kit enables the immunostaining and clearing of up to 20 samples (either one centimeter of intestinal tissue or a single lung) from mice of any age.
Protocol
Immunostaining and clearing of mouse intestine and lung for 3D imaging analysis
Fixation
1 day
Permeabilization
7 days
Immunostaining
1 day
Washing
2 days
Dehydration
6 h
Clearing
Imaging
Protocol
Preparation of PFA buffer
- All steps that include paraformaldehyde (PFA) must be performed under a fume hood.
- The protocol describes the preparation of 500 mL of 4% PFA buffer. For higher or lower volumes scale the amounts of the components accordingly.
- Do not use ready-to-use PFA solutions.
- Add 20 g of PFA powder to 400 mL of PBS and stir the mixture at 60 °C under a fume hood until it is dissolved.
▲ Note: Do not boil.
▲ Note: PFA powder does not dissolve instantly. - Add 0.2–0.4 g of NaOH and continue stirring at 60 °C until the solution clears up. This may take 2–3 hours.
- Adjust the pH to 7.2–7.4 with HCl and NaOH.
- Adjust the volume to 500 mL with PBS.
- Filter the solution using a 0.22 µm filter.
- Store PFA buffer at 4 °C for one week. For long-term storage prepare aliquots and store at –20 °C. Avoid repeated freeze/thaw cycles.
Preparation of 1× Antibody Staining Solution
- If precipitates occur due to storage of the 10× Antibody Staining Solution at low temperature, mix well before preparation of 1× Antibody Staining Solution.
- 10× Antibody Staining Solution from the MACS Clearing Kit needs to be diluted 1:10 with sterile distilled water before use, e.g., by diluting 1 mL of 10× Antibody Staining Solution with 9 mL of sterile distilled water. Adjust the volume of 1× Antibody Staining Solution according to the number of samples to be cleared.
- Always use freshly prepared 1× Antibody Staining Solution.
Preparation of ethanol/Tween® 20 dilutions for dehydration
- The following solutions are needed:
- Ethanol 30%/Tween® 20
- Ethanol 50%/Tween® 20
- Ethanol 70%/Tween® 20
- Ethanol 90%/Tween® 20
- Absolute (≥99.8%) ethanol/Tween® 20
- Prepare ethanol dilutions of 30%, 50%, 70%, and 90% in water. Use absolute ethanol (≥99.8%) and sterile distilled water to prepare the dilutions. Add Tween® 20 to each dilution for a final concentration of 2%.
▲ Note: Make sure to use fresh absolute ethanol (≥99.8%) that does not contain water residues.
Preparation of Clearing Solution
- Clearing Solution is ready-to-use, but may freeze when stored at 2–8 °C. Therefore, it is recommended to prepare aliquots and store at 2–8 °C. Bring aliquots to room temperature (20–25 °C) before proceeding to clearing of samples.
▲ Note: Use polypropylene tubes for preparation of aliquots. Other plastics might not be compatible with the Clearing Solution.
- For details on the reagents of the MACS Clearing Kit refer to the respective data sheet.
- Use tweezers to handle the samples.
2.1 Fixation
- Extract sample and collect it in a tube containing PBS/EDTA buffer.
▲ Note: If working with intestine, rinse it thoroughly with PBS/EDTA buffer before proceeding. - Transfer sample into a new tube containing PFA buffer.
▲ Note: It is possible to fix more than one sample per tube. Make sure samples are fully immersed in PFA buffer. - Incubate overnight at 2–8 °C.
▲ Note: In order to avoid autofluorescence, do not extend the incubation time. - Wash sample 3× in PBS.
▲ Note: If not immediately processed for clearing, samples can be stored in PBS/azide buffer at 2–8°C for several weeks.
2.2 Permeabilization
- Add 5 mL of Permeabilization Solution of the MACS Clearing Kit into a 5 mL tube.
- Transfer either one centimeter of intestine tissue or a single lung into the tube.
- Incubate for at least 24 hours at room temperature (20–25 °C) under slow continuous rotation using the MACSmix™ Tube Rotator.
- After incubation discard Permeabilization Solution and immediately proceed to section 2.3 Immunostaining and washing.
2.3 Immunostaining and washing
- Perform all incubation steps protected from light.
- The following protocol has been optimized for fluorochrome-conjugated primary antibodies from Miltenyi Biotec. Refer to the respective Miltenyi Biotec antibody conjugate data sheet or product page for the recommended dilution. When using other antibodies refer to the manufacturer´s recommendations for antibody dilution, incubation temperature, and duration of incubation.
- Dilute the primary antibody in a final volume of 1.5 mL of 1× Antibody Staining Solution. Use a 24-well plate to prepare the dilution.
- Transfer sample into the 24-well plate containing the antibody dilution.
- Carefully seal the plate with PARAFILM® M to prevent evaporation.
- Incubate sample with gentle shaking using a horizontal shaker. When using Miltenyi Biotec antibodies, incubate for 7 days at 37 °C.
- Washing step 1: Add 5 mL of 1× Antibody Staining Solution into a 5 mL tube. Transfer sample into this tube. Incubate sample under slow, continuous rotation for 4 hours at room temperature (20–25 °C) using the MACSmix Tube Rotator.
- Washing step 2: Discard 1× Antibody Staining Solution and repeat step 5.
- Washing step 3: Discard 1× Antibody Staining Solution and perform one additional washing step with 5 mL of 1× Antibody Staining Solution. Incubate overnight at room temperature (20–25 °C) under slow, continuous rotation using the MACSmix Tube Rotator.
- If working with fluorochrome-conjugated primary antibodies, discard 1× Antibody Staining Solution and continue with section 2.5 Dehydration (or optionally to 2.4 Embedding). If performing indirect staining, follow steps 9–11.
- Dilute secondary antibody in a final volume of 1.5 mL of 1× Antibody Staining Solution. Use a new 24-well plate to prepare the dilution.
▲ Note: Refer to manufacturer’s recommendations for optimal antibody dilution. - Incubate sample in secondary antibody dilution with gentle shaking using a horizontal shaker.
▲ Note: Refer to manufacturer’s recommendations for incubation temperature and duration of incubation. - Proceed with the washing steps above (steps 5–7).
2.4 (Optional for intestine) Embedding
- Embedding is optional for intestine and not necessary for lung tissue.
- Perform all incubation steps protected from light.
- For gel preparation dissolve 1.5% agarose in double-distilled water or 1% Phytagel™ in tap water by heating it up in a microwave.
- Fill the lumen of the intestinal sample with liquid agarose. Use a syringe, pipette, or something similar.
▲ Note: Make sure that the liquid gel is not too hot. The glass bottle for gel preparation should be touchable by hand. - Gently transfer the sample to a cryomold using forceps.
- Add 1 mL liquid gel to the crymold on top of the sample.
- Wait 10–20 minutes until the gel solidifies.
- Trim the gel block to approximately 1 mm2 around the intestinal sample.
2.5 Dehydration
- Perform all incubation steps protected from light.
- 15 mL tubes must be completely filled with the corresponding ethanol/Tween® 20 dilution.
- Always use a new tube for each dehydration step. Transfer the sample into the tube using tweezers.
- Dehydrate sample by incubating in a series of ethanol dilutions in 15 mL tubes (one sample per tube) at room temperature (20–25 °C) under slow, continuous rotation using the MACSmix Tube Rotator.
▲ Note: All 4 hour incubation steps can be extended to overnight incubation.
- Incubation in 30% ethanol/Tween® 20 for 4 hours
- Incubation in 50% ethanol/Tween® 20 for 4 hours
- Incubation in 70% ethanol/Tween® 20 overnight
- Incubation in 90% ethanol/Tween® 20 for 4 hours
- Incubation in absolute (≥99.8%) ethanol/Tween® 20 for 4 hours
- Incubation in absolute (≥99.8%) ethanol/Tween® 20 overnight
▲ Note: Replace absolute (≥99.8%) ethanol from the previous step with fresh absolute (≥99.8%) ethanol and incubate overnight.
2.6 Clearing
- Perform all incubation steps protected from light.
- Add 5 mL of Clearing Solution of the MACS Clearing Kit into a 5 mL amber polypropylene tube.
▲ Note: Always use polypropylene tubes to incubate samples with the Clearing Solution of the MACS Clearing Kit. - Transfer one dehydrated sample into this tube.
▲ Note: Make sure the tube is completely filled with Clearing Solution. Add additional Clearing Solution if necessary to fill up the tube completely. - Incubate at room temperature (20–25 °C) under slow continuous rotation for 6 hours using the MACSmix Tube Rotator.
- Discard Clearing Solution and continue with downstream imaging analysis.
▲ Note: Cleared samples can be stored in 5 mL polypropylene or glass tubes filled with MACS Imaging Solution at room temperature for several months.
▲ Note: Do not store cleared sample at 2–8°C, otherwise freezing artefacts and tissue damage may occur - Optional) If image acquisition is performed immediately after clearing, transfer cleared sample into the imaging chamber of a light sheet microscope (e.g. Ultramicroscope II or Ultramicroscope Blaze). Fill imaging chamber with MACS Imaging Solution and proceed with analysis.
▲ Note: If not using UltraMicroscope Platforms, refer to the respective manual and data sheet for compatibility of instrument and sample holders.
3 products found
|
Catalog no. was copied to your clipboard
For research use only
Price
7.176,00 DKK
(excl. tax)
Catalog no. was copied to your clipboard
For research use only
Size
450 mL
450 mL
Price
2.996,00 DKK
(excl. tax)
Catalog no. was copied to your clipboard
For research use only
Size
1 kit
1 kit
Price
7.004,00 DKK
(excl. tax)
You have previously chosen International as your location.
What do you want to do?