NKG2A/C/E Antibody, anti-mouse, REAfinity™
Synonyms: CD159a, CD159c, CD159e, NKG2A, KLRC1, NKG2C1, KLRC2, NKG2E, KLRC3
RECOMBINANT EXTENDED VALIDATION
Bioz Star93/100 Bioz rating
1 Citation
Clone:
REA1100 | 20d5
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
FC, MICS, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for NKG2A/C/E Antibody, anti-mouse, REAfinity™

Flow cytometry applications
APC
APC-Vio 770
PE
PE-Vio 615
PE-Vio 770
Vio Bright B515
Recommended dilution:
1:50
Remark:
Cells should be stained prior to fixation, if formaldehyde is used as a fixative.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-119-239
Description:
Splenocytes from C57BL/6 mice were stained with Anti-NKG2A/C/E antibodies or with the corresponding REA Control antibodies (left images) as well as with CD49b antibodies and analyzed by flow cytometry using the MACSQuant® Analyzer. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application imageView details view details

Application imageView details view details
MICS (MACSima Imaging Cyclic Staining) applications
APC
PE
Fixation:
frozen – Acetone
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-119-239
Testing grade:
Extended validation for NKG2A/C/E Antibody, anti-mouse, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA1100
20d5
high

Cells were incubated with an excess of purified unconjugated NKG2A/C/E (REA1100) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for NKG2A/C/E. Splenocytes from C57BL/6 mice were stained with NKG2A/C/E antibodies followed by a suitable counterstain. As a control, NKG2A/C/E antibody staining was omitted and cells were measured in the same channel. Flow cytometry analysis was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. The recommended titers of respective antibodies from different suppliers were used.

Extended-Validation detailed information image

Flow cytometric comparison of different clones for NKG2A/C/E shown as histograms

Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using NKG2A/C/E (REA1100). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for NKG2A/C/E Antibody, anti-mouse, REAfinity™
Overview

Clone REA1100 recognizes the mouse NKG2A, NKG2C, and NKG2E antigen on a subset of natural killer (NK) and NK-T cells in most mouse strains, for example, AKR/J, BALB/c, C3H/He,C57BL/6, CBA/J, DBA/1, FVB/N, 129/Sv, NOD, SWR, and most DBA/2 substrains, but not DBA/2J. The C-type lectin-like NKG2 receptors form heterodimers of CD94 and one of several NKG2 family members, i.e., NKG2A (CD159a), NKG2C (CD159c), or NKG2E. CD94/NKG2 receptors monitor classical class I expression indirectly by means of the recognition of classical class I signal peptides. These signal peptides are processed to a nonameric peptide called Qdm that is presented to CD94/NKG2+ NK cells by a non-classical MHC class I molecule called Qa-1. CD94/NKG2 receptors equip NK cells with the capacity to detect cells with abnormal MHC class I expression, such as often results from viral infection or transformation.

Additional information: Clone REA1100 displays negligible binding to Fc receptors.

Alternative names

CD159a, CD159c, CD159e, NKG2A, KLRC1, NKG2C1, KLRC2, NKG2E, KLRC3

Detailed product information

Technical specifications

Clone
REA1100
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody, human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
mouse
Antigen
NKG2A/C/E
Molecular mass of antigen [kDa]
28
Distribution of antigen
NK cells, NKT cells
Entrez Gene ID
RRID
AB_2733165, AB_2733009, AB_2733443, AB_2734050, AB_2733278, AB_2734049, AB_2733010, AB_2733885, AB_2733884

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for NKG2A/C/E Antibody, anti-mouse, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

You have previously chosen International as your location.
What do you want to do?