NF-κB p65 pS529 Antibody, anti-human, REAfinity™
Synonyms: NFKB1, EBP-1, KBF1, NF-kB1, NFKB-p105, NFKB-p50, p105, p50, NF-kB
RECOMBINANT EXTENDED VALIDATION
Bioz Star94/100 Bioz rating
4 Citations2 Images
Clone:
REA348 | K10-895.12.50
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
ICFC, MICS, IF, IHC, MC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for NF-κB p65 pS529 Antibody, anti-human, REAfinity™

Intracellular flow cytometry applications
APC
FITC
PE
Recommended dilution:
1:50
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-124-298, 130-124-251
Description:
Human peripheral blood mononuclear cells (PBMCs), overnight serum starved and either left unstimulated (left image) or stimulated with 100 ng/mL PMA and 1 µg/mL Ionomycin for 15 minutes at 37 °C, were fixed and permeabilized using the Cell Signaling Buffer Set A. Cells were then stained with Anti-NF-κB p65 pS529 antibodies as well as with CD3 antibodies and analyzed by flow cytometry using the MACSQuant® Analyzer. Cell debris were excluded from the analysis based on scatter signals.

Application imageView details view details

Application imageView details view details
MICS (MACSima Imaging Cyclic Staining) applications
APC
FITC
PE
Fixation:
frozen – PFA
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-124-298, 130-124-251
Testing grade:
Mass cytometry applications
pure
Conjugate:
pure
Used products:
130-124-528
Extended validation for NF-κB p65 pS529 Antibody, anti-human, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA348
K10-895.12.50
high
B33B4WP
high
14G10A21
low

Cells were incubated with an excess of purified unconjugated NF-κB p65 pS529 (REA348) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Specifications for NF-κB p65 pS529 Antibody, anti-human, REAfinity™
Overview

Clone REA348 recognizes the human NF-κB p65 antigen phosphorylated at serine 529 (pS529). NF-κB is a pleiotropic transcription factor present in almost all cell types and is the endpoint of a series of signal transduction events that are initiated by a vast array of stimuli related to many biological processes such as inflammation, immunity, differentiation, cell growth, tumorigenesis, and apoptosis. It is a homo- or heterodimeric complex and the heterodimeric p65-p50 complex is the most abundant one. Optimal induction of NF-κB target genes also requires phosphorylation of NF-κB proteins, such as p65, within their transactivation domain by a variety of kinases in response to distinct stimuli.

Additional information: Clone REA348 displays negligible binding to Fc receptors.

Alternative names

NFKB1, EBP-1, KBF1, NF-kB1, NFKB-p105, NFKB-p50, p105, p50, NF-kB

Detailed product information

Technical specifications

Clone
REA348
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody (I), human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
human
Antigen
NF-κB p65 pS529
Molecular mass of antigen [kDa]
60, average of subunits
Distribution of antigen
other
Entrez Gene ID
RRID
AB_2889720, AB_2889718, AB_2905348, AB_2889716, AB_2889719, AB_2905347, AB_2889717

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for NF-κB p65 pS529 Antibody, anti-human, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

You have previously chosen International as your location.
What do you want to do?