▲ Review the data sheets for all reagents used, as well as the Materials section of this protocol, before starting the procedure to ensure that all required reagents and instruments are available and ready for use.
▲ StraightFrom Buffy Coat MicroBeads, human, are designed for the positive selection of target cells from buffy coat samples with volumes of up to 80 mL. For larger sample volumes, please contact our Technical Support team.
▲ Work fast, keep cells cold, and use pre-cooled solutions (+2 to +8 °C). This will prevent capping of antibodies on the cell surface and non-specific cell labeling.
▲ The volumes indicated below for magnetic labeling are optimized for one complete buffy coat (up to 80 mL). If smaller buffy coat fractions are used, reduce all reagent amounts and total volumes proportionally. As an example, for half a buffy coat, adjust the final volume to 40 mL and add 2 mL of StraightFrom Buffy Coat MicroBeads, human.
▲ For optimal performance, ensure that a single-cell suspension is obtained prior to magnetic labeling. To remove cell aggregates that may clog the column, pass the cell suspension through a 30 µm nylon mesh (MACS SmartStrainers (30 µm), #130-098-458). Pre-wet the filter with buffer before use.
▲ The recommended incubation temperature is +2 to +8 °C. Higher temperatures and/or longer incubation times may lead to non-specific cell labeling. Working on ice may require increased incubation times.