The MACSQuant® Tyto® Cartridge LC (large cell) has been specifically designed to facilitate sorting of large-sized cell types on the MACSQuant Tyto Cell Sorter, enabling the sorting of cells with diameters up to 50 μm. In addition, due to its cutting-edge microfluidic pathway, the MACSQuant Tyto Cartridge LC also features inertial cell focusing to improve sorting speed and sorting performance.
As in the other MACSQuant Tyto Cartridges, the patented microchip technology of the MACSQuant Tyto Cartridge LC enables fluorescence-based and aerosol-free cell sor
The MACSQuant® Tyto® Cartridge LC (large cell) has been specifically designed to facilitate sorting of large-sized cell types on the MACSQuant Tyto Cell Sorter, enabling the sorting of cells with diameters up to 50 μm. In addition, due to its cutting-edge microfluidic pathway, the MACSQuant Tyto Cartridge LC also features inertial cell focusing to improve sorting speed and sorting performance.
As in the other MACSQuant Tyto Cartridges, the patented microchip technology of the MACSQuant Tyto Cartridge LC enables fluorescence-based and aerosol-free cell sorting with a fast mechanical sort valve (up to 12,500 valve actuations per second) in a fully closed environment, providing complete operator safety.
The MACSQuant Tyto Cartridge LC is a single-use disposable that diminishes any risk of sample cross-contamination. Both positive and negative sorted fractions remain in the MACSQuant Tyto Cartridge HS after the actual sort, allowing full retrieval of all cells within the sample.
ATTENTION:
To be able to run the MACSQuant Tyto Cartridge LC on your MACSQuant Tyto Cell Sorter, MACSQuantify™ Tyto Software version 3.2 or higher is required! For further information, please contact technical support.
The MACSQuant Tyto Cartridge LC consists of three compartments that can each be accessed from above through individual, aseptic Luer-Locks: the input chamber, the positive collection chamber, and the negative collection chamber.
Cells suspended in the specially formulated MACSQuant Tyto Running Buffer are loaded into the input chamber of the MACSQuant Tyto Cartridge. The input chamber contains an adjustable propeller, which keeps cells in suspension during the sort.
After loading the cartridge into the instrument, filtered air is applied to the input chamber through a pressure inlet. Driven by moderate air pressure, fluorescently labeled cells flow from the input chamber through an inertial focusing microchannel into the microchip. Within the microchip, cells are interrogated by lasers. Fluorescent and scatter light signatures are used to select target cells, which are then redirected by a sort valve located within the sorting channel.
To gently redirect a target cell into the positive collection chamber, a magnetic field is applied to the microchip. This triggers the sorting valve to open and therefore change the flow of the target cell towards the positive collection chamber.
After a target cell has passed through, a silicon spring returns the valve into its original position. Unlike during conventional droplet sorting procedures, the cells do not experience very high pressures of up to 70 psi, and therefore are not as strongly decompressed as in these systems. In addition, no charge is applied, and the cells experience only very mild shear forces, resulting in a high viability and functionality of the sorted cells.
The sorting mechanism of the MACSQuant Tyto Cell Sorter. Coming from the input chamber, cells enter the microchip through a microchannel where they are interrogated by three lasers. Before entering the microchannel, potential cell aggregates are held back by a filter system, guaranteeing a smooth sorting process. When a target cell (magenta) is identified, a magnetic pulse coming from the solenoid opens the microvalve, which then redirects the target cell into the positive collection chamber. In the default state, the valve is closed allowing non-selected cells (blue and orange) to flow through into the negative collection chamber.
The MACSQuant Tyto Cartridge LC, side view
The MACSQuant Tyto Cartridge LC, bottom view
The MACSQuant Tyto Cartridge LC, bottom view showing the inertial focusing interposer, including the mounted microchip