CD68 Antibody, anti-mouse, REAfinity™
Synonyms: Lamp4, SCARD1, gp110, macrosialin
RECOMBINANT EXTENDED VALIDATION
Bioz Star94/100 Bioz rating
15 Citations6 Images
Clone:
REA835 | FA-11
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
ICFC, MICS, 3D-IF, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for CD68 Antibody, anti-mouse, REAfinity™

Intracellular flow cytometry applications
APC
APC-Vio 770
Biotin
FITC
PE
PE-Vio 615
PE-Vio 770
PerCP-Vio 700
Vio B515
VioBlue
VioGreen
Recommended dilution:
1:50
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-112-668, 130-112-857
Description:
Splenocytes of C57BL/6 mice were fixed, permeabilized, and stained with CD68 antibodies or the corresponding REA Control antibodies (left peak). Cells were pre-gated with Anti-F4/80 antibodies. Flow cytometry was performed using the MACSQuant® Analyzer. Cell debris were excluded from the analysis based on scatter signals.

Application image
MICS (MACSima Imaging Cyclic Staining) applications
APC
FITC
PE
Fixation:
frozen – PFA
Species tested:
mouse
Tissue used:
frontal cortex
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-112-668, 130-112-857
Testing grade:
Description:
Immunofluorescence analysis of a Frontal Cortex cryosection fixed with 4% PFA. The section was stained using CD68 APC (green) and CD11b PE (red) for 10 min at room temperature. Nuclei were visualized with Hoechst™ (blue). Scale bar: 30 µm.

Application image
Fixation:
frozen – Acetone
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-112-668, 130-112-857
Testing grade:
3D-Immunofluorescence applications
Vio 780
Vio B515
Vio G570
Vio R667
Tissue clearing:
MACS® Clearing Kit
Fixation:
PFA
Species tested:
mouse
Tissue used:
lymph node
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
Vio 780
Used products:
130-135-524
Protocols:
Immunostaining and clearing of mouse lymph nodes for 3D imaging analysis.
Description:
3D-immunofluorescence analysis of mouse lymphnodes fixed with 4% PFA and subjected to whole-mount immunostaining with CD68 Antibody, mouse, Vio® 780 (magenta). The sample was processed and optically cleared using the MACS® Clearing Kit and imaged with an UltraMicroscope Blaze light sheet instrument. Sample detail image of lymphnodes (A), overview of lymphnode (B). Scale bars: 100 µm (A), 500 µm (B).

A

Application imageView details view details

B

Application imageView details view details
Extended validation for CD68 Antibody, anti-mouse, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA835
FA-11
partial

Cells were incubated with an excess of purified unconjugated CD68 (REA835) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD68. Mouse splenocytes were first stained with Viobility™ Fixable Dye followed by a suitable counterstaining. Cells were then fixed and permeabilized using the Inside Stain Kit followed by a staining with CD68 antibodies. As a control, CD68 antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and Viobility 405/452 Fixable Dye fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Specifications for CD68 Antibody, anti-mouse, REAfinity™
Overview

Clone REA835 recognizes mouse CD68 antigen, also known as macrosialin, which is a heavily glycosylated type I transmembrane protein of the lysosomal-associated membrane protein (LAMP) family. It is expressed on tissue macrophages, Langerhans cells, and at a low density on dendritic cells. Murine CD68 is predominantly intracellular but it is reported that 10–15% of CD68 is expressed on the cell surface as well. Macrosialin functions as a macrophage receptor for oxidized low density lipoprotein.

Additional information: Clone REA835 displays negligible binding to Fc receptors.

Alternative names

Lamp4, SCARD1, gp110, macrosialin

Detailed product information

Technical specifications

Clone
REA835
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody, human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
mouse
Antigen
CD68
Molecular mass of antigen [kDa]
33
Distribution of antigen
macrophages, dendritic cells, Langerhans cells
Entrez Gene ID
RRID
AB_2659031, AB_2659037, AB_2659027, AB_2905105, AB_2922178, AB_2659032, AB_2659039, AB_2659030, AB_2659021, AB_2659036, AB_2659038, AB_2659035, AB_2659023, AB_2659033, AB_2659025, AB_2659034, AB_2659028, AB_2659040, AB_2659026, AB_2659029, AB_2659022, AB_2659024

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for CD68 Antibody, anti-mouse, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

You have previously chosen International as your location.
What do you want to do?